background image

40985_G

12-06-13

13

Manufactured under one or more of these patents.  U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2, 
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.   All material copyright of Balboa Water Group.

Additional Settings

Hold Mode - M037*

Hold Mode is used to disable the pumps during service functions like cleaning or replacing the filter. Hold Mode will last 
for 1 hour unless the mode is exited manually. If spa service will require more than an hour, it may be best to simply shut 
down power to the spa.

Drain Mode

Some spas have a special feature that allows Pump 1 to be employed when draining the water.  
When available, this feature is a component of Hold Mode.

Utilities 

The Utilities Menu contains the following:

A/B Temps 

When this is set to On, the temperature display will alternate to display temperature from Sensor A and Sensor B in 
the heater. 

Demo Mode 

Demo Mode is not always enabled, so it may not appear. This is designed to operate several devices in a sequence in 
order to demonstrate the various features of a particular hot tub. 

Fault Log 

The Fault Log is a record of the last 24 faults that can be  
reviewed by a service tech.

GFCI Test  
(Feature not available on CE rated systems.) 

GFCI Test is not always enabled, so it may not appear. This screen 
allows the GFCI to be tested manually from the panel and can be 
used to reset the automatic test feature. If the GFCI Test Feature 
is reset, the device will trip within 7 days. (See Page 16)

Fault Log

Back

Entry 2
  Message Code M026
     1 Days Ago     2:21PM
  Rest Mode
  High Range
  Set Temp 104°F
  Sensors: A: 100   B: 96

Message:
Sensors are out of sync

*M036 is a Message Code. Codes like this will be seen in the Fault Log 

Summary of Contents for BP2 Series

Page 1: ...ts both foreign and domestic applied for and pending All material copyright of Balboa Water Group TP800 and TP900 Series Control Panels Balboa Water Group BP2XXXX Series User Interface and Programming...

Page 2: ...desired or Set Temperature can be selected and adjusted Time of day Ozone operation and Filter Operation status is available along with other messages and alerts High Temperature Range vs Low Temperat...

Page 3: ...et Temperature Press the Left Arrow button to change the Set Temperature number to white The Set Temperature can then be adjusted with the up and down buttons Pressing the Select button or the Right A...

Page 4: ...er the icon changes to white Once a device is selected it can be controlled using the center Select Button Some devices like pumps may have more than one ON state so the icon will change to reflect th...

Page 5: ...ce while on the Shortcuts Screen if the device is one of the 4 functions available Settings Back Temp Range Heat Mode Time of Day Filter Cycles Light Cycle Invert Panel Lock High Ready Normal Press an...

Page 6: ...t temperature until the heater pump has been running for a minute or two While Pump 1 High can be turned on and off Pump 1 Low will run until set temperature is reached or 1 hour has passed Circulatio...

Page 7: ...on Priming the Pumps As soon as the Priming Mode screeen appears on the panel select the Jets 1 button once to start Pump 1 in low speed and then again to switch to high speed Also select the other pu...

Page 8: ...ze conditions or when another pump is on The specific Circulation Mode that is used has been determined by the Manufacturer and cannot be changed in the field Other device options may be available lik...

Page 9: ...Day screen simply navigate right and left to select the Hour Minutes AM PM and 12 24 Hour segments Use the Up and Down Buttons to make changes Saving Settings The Time of Day screen is a simple edita...

Page 10: ...ycle 1 by navigating to the right It is possible to overlap Filter Cycle 1 and Filter Cycle 2 which will shorten overall filtration by the overlap amount Circulation Pump Modes Some spas may be manufa...

Page 11: ...default The settings can be edited the same way that Filter Cycles are edited see page 10 Specific Buttons for Specific Devices If the panel has dedicated function buttons TP800 or the spa has an Auxi...

Page 12: ...both Panel Lock and Settings Lock The control can be restricted to prevent unwanted use or temperature adjustments Locking the Panel prevents the controller from being used but all automatic function...

Page 13: ...ode Utilities The Utilities Menu contains the following A B Temps When this is set to On the temperature display will alternate to display temperature from Sensor A and Sensor B in the heater Demo Mod...

Page 14: ...minders Turn the reminder messages like Clean Filter On or Off Cleanup Cleanup Cycle Duration is not always enabled so it may not appear When it is available set the length of time Pump 1 will run aft...

Page 15: ...tem Model Displays the Model Number of the System Current Setup Displays the currently selected Configuration Setup Number Configuration Signature Displays the checksum for the system configuration fi...

Page 16: ...t off until a service person can correct the problem Forcing the GFCI Trip Test North America Only The installer can cause the GFCI Trip Test to occur sooner by initiating it using the above menu The...

Page 17: ...essage can be selected by navigating to it at pressing the Select button The water is too hot M029 The system has detected a spa water temp of 110 F 43 3 C or more and spa functions are disabled Syste...

Page 18: ...n heater start up The heater may be dry M028 Possible dry heater or not enough water in the heater to start it The spa is shut down for 15 min Press any button to reset the heater start up See Flow Re...

Page 19: ...r 3 F Call for Service Sensors are out of sync Call for service M026 The temperature sensors ARE out of sync The fault above has been established for at least 1 hour Call for Service Sensor A Fault Se...

Page 20: ...organization The GFCI test failed System Could Not Test the GFCI M036 North America Only May indicate an unsafe installation Contact your dealer or service organization Hot fault M035 A Pump Appears t...

Page 21: ...or RCD associated with the hot tub installation A GFCI or RCD will have a TEST and RESET button on it that allows a user to verify proper function General maintenance helps Reminder Messages can be s...

Page 22: ...nstruction manual Adequate drainage must be provided if the equipment is to be installed in a pit For use only within an enclosure rated CSA Enclosure 3 Connect only to a circuit protected by a Class...

Reviews: