Changing Software Setups with TP600 / TP400 Continued

Again, 

You will have 1 minute 

to complete the setup change after you manually exit Priming Mode. 

Immediately after exiting Priming Mode, press this sequence of buttons:  Warm*, Light, Warm, Warm, Warm, Warm. Continue to press Warm until the diplay 
shows the Setup Number (S-01, S-02, etc.) you want to switch to.  When the correct setup number is showing, press Light once, and the system will reset, 
using the newly-selected Setup from that point on.
Move DIP Switch 1 to the OFF position to take the spa out of Test Mode. °F or °C will replace °T.

Using a permanent marker, write the Setup number on the Setup label mounted inside the system lid (right).  This is very important to any service 

person in the future who may need to replace a circuit board or system and needs to change the Setup on a replacement part while in the field.

NOTE: Changing the Setup may require wiring changes as well - refer to the wiring diagram or wiring diagram addendum.

THIS SYSTEM IS

CONFIGURED AS

SETUP #

Indicates Flashing or Changing Segment

Key

A temperature button, used for “Action” 
Light or dedicated “Choose” button, depending on control panel configuration 

Indicates Alternating or Progressive Message - every 1/2 second

Waiting time - varies depending on function

05/12/09

Main Menus with Test Mode (S1 ON) Details

SET

SET

The System will reset and go into Priming Mode if the Light Button 

is pressed while anything other than the current setup is flashing. 

If there is no change to the Setup Number (S-01, S-02, etc.), 

the display returns to the SETP screen. 

Several Setups can 

exist in in this string

A dash (--) indicates the current Setup.

SET

SET

SET

SET

SET

SET

SET

While the Set Temperature is 

still flashing, press Light

TEST will now appear in 

the LCD first.

SET

RANGE

Main Screen

READY

RANGE FLTR1

Main Screen

READY

RANGE FLTR1

SET

Approx.

5 sec.

or

Approx.

5 sec.

or

SET

SET

SET

SET

When set to ON, Panel will display 

alternate readings from 

Senor A  and Sensor B 

on Main Screen

Displays Fault Log

*If the Control Panel does not have a Warm (Up) button, but 
rather a single Temp button, use the Temp button in place 
of the Warm button in the instruction above. (The flow chart 
assumes a single Temperature Button.)

Note: The Timeouts and Spa O/H 
selections should NEVER be changed. 
They are for safety agency testing 
purposes only.

Summary of Contents for BP100G2

Page 1: ...ation Signature F402B0EF Eng Project Number 5205 Control Panels See later pages for more information spaTouch 2 Any version version 2 0 or later required for bba 2 fully integrated functionality Icon...

Page 2: ...19 Part EPN Date Originator Changes Made 59267 59268 5205 05 01 19 BWG Generic BP100G2 system supporting most of the Setups the BP100 board can do with a pump expander board System Revision History bb...

Page 3: ...TE The above 120V spec is only when using a wall mount GFCI breaker If using a GFCI cord the breaker is 15A and so the service is limited to 12A BP systems automatically detect 50Hz vs 60Hz However po...

Page 4: ...deliver 20 GPM through heater 1 Speed in Setups 1 3 Pump 2 240VAC 1 Speed 12A max 15 minute timer Unused in Setups 3 4 Circ Pump 240VAC 1 Speed 2A max Programmable Filtration Cycles Polling This is th...

Page 5: ...J15 SPA LIGHT 10V 1A PUMP 1 CIRC AND OZONE ALL MUST BE THE SAME VOLTAGE SENSOR A SENSOR B 5 5 kW HEATER TORQUE RANGE FOR HEATER CONNECTIONS 30 TO 35 IN LBS EXPANDER X P J3 PUMP 2 K1 J6 J2 W12 EXPANDE...

Page 6: ...Australian patent 2373248 other patents both foreign and domestic applied for and pending Copyright 2009 Balboa Water Group 59267_59268_A 05 13 19 Setup Reference Table Setup Circ Pump Pump 1 Pump 2 T...

Page 7: ...ftware Setups While in Test Mode press the indicated icons to move from screen to screen ON 1 10 S1 Changing Software Setups with spaTouch Icon Driven Panels Once on the Setup Selection screen press t...

Page 8: ...ng move DIP Switch 1 on S1 on the Main circuit board to ON The system will enter Test Mode Moving DIP Switch 1 to OFF will exit Test Mode Software Setups Under the TEST Menu the Setup screen will allo...

Page 9: ...The system will enter Test Mode Moving DIP Switch 1 to OFF will exit Test Mode Software Setups Under the TEST Menu the Setup screen will allow changing the Setup from 1 to any number established by t...

Page 10: ...e Setup may require wiring changes as well refer to the wiring diagram or wiring diagram addendum THIS SYSTEM IS CONFIGURED AS SETUP Indicates Flashing or Changing Segment Key A temperature button use...

Page 11: ...6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending Copyright 2009 Balboa Water Group 59267_...

Page 12: ...e spa is powering up to restore factory settings as determined by software configuration A2 and A3 work in combination to determine the number of high speed devices and blowers that can run before the...

Page 13: ...t be enabled in software as well J30 Do Not Use J31 Jumper on 1 pin when heater voltage is 120V Jumper on 2 pins when heater voltage is 240V J24 Jumper on center two pins 240V when heater voltage is 2...

Page 14: ...her patents both foreign and domestic applied for and pending Copyright 2009 Balboa Water Group 59267_59268_A 05 13 19 Replacement Parts PCBA Main PCBA 59269 Expander PCBA 59232 HEATER s Heater 58421...

Page 15: ...l Pump Timer 15 Minutes Blower Timer 15 Minutes Mister Timer 15 Minutes Light Timer 240 Minutes Circ when enabled Programmable Polling Circ Pump can be set with the following functions 24 hr 24 hr w 3...

Page 16: ...for default settings choose a desired C value that after rounding cor responds to a Fahrenheit value C 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 F 39 41 43 45 46 48 50 52 54 55 57 59 61 63 6...

Page 17: ...2 Hour 12 Hour 24 Hour N A Filter 1 Start Hour 20 00 8 00 PM 00 00 to 23 00 1 Hour Filter 1 Duration 2 Hours Between 15 Min and 23 45 15 Minutes or continuous Filter Cycle 2 Default OFF OFF ON N A Fil...

Page 18: ...ders Shown Yes Yes No N A Check pH OFF See Reminder Period Note 1 Days Check Sanitizer OFF See Reminder Period Note 1 Days Clean Filter 30 Days See Reminder Period Note 1 Days Test GFCI OFF See Remind...

Page 19: ...igh speed together Blower can be allowed or suppressed when number of pumps selected is reached No Limitation does not restrict pump or blower operation DIP Switch 5 is used to choose Special Amperage...

Page 20: ...4 1 N A N A N A N A 2 Jets 1 Jets 1 Jets 1 Jets 1 3 Jets 2 Jets 2 Light Light 4 Light Light Invert Invert 5 Invert Invert Circ Icon Undefined 6 Circ Icon Undefined Undefined Undefined 7 Undefined Und...

Page 21: ...Jets 1 A3 Jets 2 Jets 2 Light 1 Light 1 A4 Light 1 Light 1 Invert Invert A5 Invert Invert Circ Icon Undefined A6 Circ Icon Undefined Undefined Undefined A7 Undefined Undefined Undefined Undefined A8...

Page 22: ...b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending Copyright 2009 Balboa Water Group 59267_59268_A 05 13 19 TP800 Panel Configuration...

Page 23: ...reign and domestic applied for and pending Copyright 2009 Balboa Water Group 59267_59268_A 05 13 19 TP600 Panel Configuration Button Layout Table Button Setups 1 2 Setups 3 4 1 Jets 1 Jets 1 2 Jets 2...

Page 24: ...00 Panel Configuration Button Layout Table for TP400T Button Setups 1 2 Setups 3 4 1 Temperature Temperature 2 Jets 1 Jets 1 3 Light 1 Light 1 4 Jets 2 Undefined LED 1 Heater ON Heater ON LED 2 Jets 1...

Reviews: