General Messages
Most messages and alerts will appear at the bottom of the normally used screens.
Several alerts and messages may be displayed in a sequence.
The water is too hot – M029*
The system has detected a spa water temp of 110°F (43.3°C) or more, and spa functions are disabled. System will auto
reset when the spa water temp is below 108°F (42.2°C). Check for extended pump operation or
high ambient temp.
Possible freezing condition
A potential freeze condition has been detected, or the Aux Freeze Switch has closed. All water devices are activated.
In some cases, pumps may turn on and off and the heater may operate during Freeze Protection.
This is an operational message, not an error indication.
– – –°F
– – –°C
Water Temperature is Unknown
After the pump has been running for 1 minute, the temperature will be displayed.
*M0XX is a Message Code. Codes like this will be seen in the Fault Log