  ML40x/ML2xx Custom Button 1 

1

 2 3 4 5 6 b g F E o t  d P n A 

U

 r  O H 9  L  8  7

  ML40x/ML2xx Custom Button 2 

1

 2 3 4 5 6 b g F E o t  d P n A 

U

 r  O H 9  L  8  7

  ML40x/ML2xx Custom Button 3 

1

 2 3 4 5 6 b g F E o t  d P n A 

U

 r  O H 9  L  8  7

 

1-6 = 

Assigns Pump Number (Pump 1, Pump 2, etc); 

b = 

Blower; 

g = 

Spa Light; 

F = 

Fiber-Optic wheel/light; 

E = 

EitherLight; 

 

o = 

Option 1; 

t = 

Mister; 

d = 

CK Mode/Cool; 

P = 

CK Option/Heat; 

n = 

CK Intensity/TurboHt; 

A = 

ACD Aroma/Sound Mode Select; 

 

U = 

Button Disabled (DO NOT USE)

r = 

Air Valve; 

O = 

Option 2; 

H = 

Option 3; 

9 = 

Invert; 

L = 

Option 4; 

8 = 

Stir; 

7 = 

Option 5

ML400

1

2

3

ML200

3

2

1

ML260

3

2

1

ML240

3

2

1

Temp

Temp

Temp

Temp

Temp

Temp

Temp

Temp

  

 ML40x/ML2xx Custom Buttons Enable 

n

 Y   

 

 

n

 

=

 Disabled;  

Y

 

=

 Enabled; 

 

= 1 DIP Switch

 

Special Amperage Rule* 

1

  2 3 4 

 

 

1

 

=

 Blower off when 2nd high-speed pump on;  

2

 

=

 Max 1 high-speed pump 

 

 

3

 

=

 Max 2 high-speed pumps;   

 

 

4

 

=

 Max 2 high-speed pumps + Blower off when 2nd high-speed pump on 

 

*Note: DIP A11 must be ON to use Special Amperage Rule.

  Heat Cool Feature 

n

 Y   

 

 

n

 

=

 Disabled;  

Y

 

=

 Enabled; 

 

= 1 DIP Switch

 Color 

Kinetics 

n

 Y 

 

 

n

 

=

 Disabled;  

Y

 

=

 Enabled

 ACD 

n

 Y 

 

 

n

 

=

 Disabled;  

Y

 

=

 Enabled

 DR 

Mode 

n

 Y 

 

 

n

 

=

 Disabled;  

Y

 

=

 Enabled

 Demo 

Mode 

n

 Y 

 

 

n

 

=

 Disabled;  

Y

 

=

 Enabled

 Graphic 

Clock 

n

 Y 

 

 

n

 

=

 Disabled;  

Y

 

=

 Enabled (Panel must be able to support this feature)

  Sound Mode Select Enable** 

n

 Y 

(Requires correct version of sound hardware) 

 

 

n

 

=

 No;  

Y

 

=

 User Preference; 

 

= 1 DIP Switch 

 **Enables 

panel/aux/remote button access, if properly configured and User Preference access. 

 

Example: To select Sound Modes (see "So" below) by pressing Aux Button 1, configure setting "A1" to code assignment "A"

  Sound Mode Select 

A

 

n

(Values dependent on sound hardware used) 

 

 

A

 

=

 Sound choice 1;  

b

 

=

 Sound choice 2;  

c

 

=

 Sound choice 3;  

= No sounds

  GFCI Test Enable 

n

 1 2 3 4 5 6 7 

 

n

 = Disabled; 

1

 = Auto after 1 day; 

2

 = Auto after 2 days; 

3

 = Auto after 3 days; 

4

 = Auto after 4 days; 

 

5

 = Auto after 5 days; 

6

 = Auto after 6 days; 

7

 = Auto after 7 days

Software Configuration Settings Continued

ML40

X

/ML2

XX

 S

ERIES

 B

UTTONS

Summary of Contents for EL8-EL84P-YCAH

Page 1: ...756 Base PCBA PN 55889 PCB EL8000 PN 22041 Rev A HEX File 10013432_EL84P_02 hex Configuration Signature 513BFF57 Base Panels ML900 PN 54589 Aux Panels AX10A3 PN 52765 Optional Base Panel MLM990S PN 54...

Page 2: ...54775 2756 02 11 2008 Balboa New system at v31 54775 2756 04 24 2008 Balboa Update to v32 54775 2756 06 04 2008 Balboa Pages 1 19 AX40 panel PN 55487 54775 2756 09 10 2008 Balboa New Con g le Change...

Page 3: ...O ADCM J69 J20 J38 1 2 3 LK A 12VAC B J77 MAIN PANELS AUX PANELS J16 J40 J34 J31 J73 J72 J71 J70 Power Requirements s 6 Z LASS PROTECTED SERVICE IRCUIT REAKER RATING MAX s WIRES HOT HOT NEUTRAL GROUND...

Page 4: ...ration problem For example s would mean that the combination of how you ve set A5 and how you ve set B2 is not supported on this system s would mean that there is a problem with jumper J99 s would mea...

Page 5: ...em Wiring Configuration and DIP Settings Setup 1 As Manufactured Switchbank A Switchbank B B2 Assignable B3 Assignable B4 Assignable B5 Assignable B6 Assignable A5 Assignable A6 Assignable B1 Assignab...

Page 6: ...J75 J53 J95 J46 J55 J44 J52 J28 J27 J35 J43 J23 J32 TB1 FUSE 30A CLASS G FUSE 30A CLASS G F6 F7 K7 HTR2 HTR1 K6 K8 FUSE 1 2A 250V F2 K4 K3 K2 J37 K16 J7 J8 K11 K9 K10 G N G N G N J9 J11 G N J1 G N G N...

Page 7: ...ump or blower is turned on Note A2 A3 A4 all off No heat with any high speed pump or blower CFE errors are illegal configurations such as a pump and a blower set to run on the same output The configur...

Page 8: ...0 240 Volts AC Jumper on Pins 2 and 3 will power J8 pin 2 Fiber Optic Light at 12 Volts AC Note J47 and J49 must be set for the same voltage W5 controls voltage on return line of J8 pin 3 and must be...

Page 9: ...bove 1 4 number of hours 3 DIP Switch Light Timeout d 1 2 3 4 d Use Timeouts value above 1 4 number of hours Scrunch Panel n Y n Normal panel layout Y Alternate panel layout ML900 scrunching enabled M...

Page 10: ...ght and EitherLight buttons spa light enabled on SpaLight buttons only Spa Light On Off n Y n Dimmable H M L Light Y On Off Light 1 DIP Switch Fiber Optics n Y n Disabled Y Light and Wheel Enabled 2 D...

Page 11: ...tton 3 Bank B 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 Aux Button 4 Bank B 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 1 6 Assigns Pump Number Pump 1 Pump 2 etc b Blower g Spa Light F Fiber...

Page 12: ...A b C d E F g H J L n o P r Filter 2 Start Hour Set 1 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r Filter 2 Duration Set 1 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r Standard Defaults 0 0 12 a...

Page 13: ...ycle runs If 4d is set to 0 only the Day cycle runs If neither 3d nor 4d is set to 0 both the Day and Night cycles run Sets default for user preferences only applies when persistent memory is reset A1...

Page 14: ...1 2 5 4 4 5 2 3 6 7 8 DOLPHIN REMOTE ROUND REMOTE Remote Button 1 Bank B 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 Remote Button 2 Bank B 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 Remote B...

Page 15: ...4 8 7 6 5 Time Warm Warm Mode e Cool ML90x Custom Buttons Enable n Y n Disabled Y Enabled 1 DIP Switch ML75x MX75x Custom Button 1 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 ML75x MX75x Custom Bu...

Page 16: ...L55x Custom Button 1 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 ML55x Custom Button 2 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 ML55x Custom Button 3 1 2 3 4 5 6 b g F E o t d P n A U r O H...

Page 17: ...Blower off when 2nd high speed pump on Note DIP A11 must be ON to use Special Amperage Rule Heat Cool Feature n Y n Disabled Y Enabled 1 DIP Switch Color Kinetics n Y n Disabled Y Enabled ACD n Y n D...

Page 18: ...The EL circuit board is factory configured to deliver a preset voltage 120V or 240V to the on board ozone connector J4 See the ratings table on the wiring diagram attached to the cover of the enclosur...

Page 19: ...ts 1 Jets 4 Jets 3 Jets 1 Jets 2 Jets 4 AX10A3 Optional on Se Jets 1 Jets 1 Blower Blower Jets 3 Jets 1 Invert Fiber Jets 3 Time Warm Jets 1 Jets 2 Jets 3 Cool Mode Prog Invert Fiber Light F2 TL F1 PL...

Reviews: