background image

Page 10

54775_97_C

  Pump 6 Speeds 

0

 1   

   

0

 

=

 Disabled; 

1

 

=

 On/Off;     

=

 1 DIP Switch

 Blower 

Speeds 

0

 1 2 3   

   

0

 

=

 Disabled; 

1

 

=

 On/Off; 

2

 

=

 2 speeds; 

3

 

=

 3 speeds;   

=

 2 DIP Switch

  Separate Spa Light Buttons 

n

 Y   

See Chart Below 

  (This feature applies when 

n

 

=

 No Spa light button, Spa Light output is on with Fiber; 

 

using Fiber Optic light) 

Y

 

=

 Separate Spa Light button on ML900 or Aux panel 

 

 

 

=

 1 DIP Switch

Note: The Light button on an ML900 panel is a SpaLight button. The Light button on most other panels is an EitherLight button.

Lb.n

Lb.Y

Fo.n

No separately-controlled fiber light; spa light enabled on both SpaLight and EitherLight buttons; fiber light 
(not wheel) comes on with spa light (at any intensity)

Fo.Y

No separately-controlled fiber light; fiber light 
enabled on both FiberLight and EitherLight 
buttons; spa light comes on with fiber light

Spa light and fiber light each separately controlled; 
fiber light enabled on both FiberLight and EitherLight 
buttons; spa light enabled on SpaLight buttons only

  Spa Light On/Off 

n

 Y   

   

n

 

=

 Dimmable (H, M, L) Light;  

Y

 

=

 On/Off Light;    

=

 1 DIP Switch

 Fiber 

Optics 

n

 Y   

   

n

 

=

 Disabled;  

Y

 

=

 Light and Wheel Enabled;;     

=

 2 DIP Switch

 Mister 

n

 Y   

   

n

 

=

 Mister Disabled (Option Enabled on J9);  

 

 

Y

 

=

 Mister Enabled on J9 (Option Disabled);     

=

 1 DIP Switch

 Option 

1* 

n

 Y P   

 

 

n

 

=

 Disabled;  

Y/P

 

=

 Enabled on J9; 

 

= 2 DIP Switch

 Option 

2* 

n

 Y P   

 

 

n

 

=

 Disabled;  

Y/P

 

=

 Enabled on "alarm" relay; 

 

= 2 DIP Switch

 Option 

3* 

n

 Y P   

 

 

n

 

=

 Disabled;  

Y/P

 

=

 Enabled on pin 1 of X-P632 board; 

 

= 2 DIP Switch

 Option 

4* 

n

 Y P   

 

 

n

 

=

 Disabled;  

Y/P

 

=

 Enabled on pin 2 of X-P632 board; 

 

= 2 DIP Switch

 Option 

5* 

n

 Y P   

 

 

n

 

=

 Disabled;  

Y/P

 

=

 Enabled on J7; 

 

= 2 DIP Switch 

 

*Note: Options 1-5: Y = On/Off w/no timeout (toggle) mode; P = Pulse (momentary) mode

 Cleanup 

Cycles** 

0

 1 2 3  4 

   

0

 

=

 Disabled;  

1-4

 

=

 Number of hours

**Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up.

 

Cleanup Cycles as User Preference 

n

 Y 

 

 

n

 

=

 Only in Configuration Settings; 

 

 

Y

 

=

 Over-rideable by User via User Preferences

Software Configuration Settings Continued

P

UMP

 S

PEEDS

L

IGHTING

 C

ONTROL

O

PTIONS

Summary of Contents for EL8-EL84P-YCAH

Page 1: ...756 Base PCBA PN 55889 PCB EL8000 PN 22041 Rev A HEX File 10013432_EL84P_02 hex Configuration Signature 513BFF57 Base Panels ML900 PN 54589 Aux Panels AX10A3 PN 52765 Optional Base Panel MLM990S PN 54...

Page 2: ...54775 2756 02 11 2008 Balboa New system at v31 54775 2756 04 24 2008 Balboa Update to v32 54775 2756 06 04 2008 Balboa Pages 1 19 AX40 panel PN 55487 54775 2756 09 10 2008 Balboa New Con g le Change...

Page 3: ...O ADCM J69 J20 J38 1 2 3 LK A 12VAC B J77 MAIN PANELS AUX PANELS J16 J40 J34 J31 J73 J72 J71 J70 Power Requirements s 6 Z LASS PROTECTED SERVICE IRCUIT REAKER RATING MAX s WIRES HOT HOT NEUTRAL GROUND...

Page 4: ...ration problem For example s would mean that the combination of how you ve set A5 and how you ve set B2 is not supported on this system s would mean that there is a problem with jumper J99 s would mea...

Page 5: ...em Wiring Configuration and DIP Settings Setup 1 As Manufactured Switchbank A Switchbank B B2 Assignable B3 Assignable B4 Assignable B5 Assignable B6 Assignable A5 Assignable A6 Assignable B1 Assignab...

Page 6: ...J75 J53 J95 J46 J55 J44 J52 J28 J27 J35 J43 J23 J32 TB1 FUSE 30A CLASS G FUSE 30A CLASS G F6 F7 K7 HTR2 HTR1 K6 K8 FUSE 1 2A 250V F2 K4 K3 K2 J37 K16 J7 J8 K11 K9 K10 G N G N G N J9 J11 G N J1 G N G N...

Page 7: ...ump or blower is turned on Note A2 A3 A4 all off No heat with any high speed pump or blower CFE errors are illegal configurations such as a pump and a blower set to run on the same output The configur...

Page 8: ...0 240 Volts AC Jumper on Pins 2 and 3 will power J8 pin 2 Fiber Optic Light at 12 Volts AC Note J47 and J49 must be set for the same voltage W5 controls voltage on return line of J8 pin 3 and must be...

Page 9: ...bove 1 4 number of hours 3 DIP Switch Light Timeout d 1 2 3 4 d Use Timeouts value above 1 4 number of hours Scrunch Panel n Y n Normal panel layout Y Alternate panel layout ML900 scrunching enabled M...

Page 10: ...ght and EitherLight buttons spa light enabled on SpaLight buttons only Spa Light On Off n Y n Dimmable H M L Light Y On Off Light 1 DIP Switch Fiber Optics n Y n Disabled Y Light and Wheel Enabled 2 D...

Page 11: ...tton 3 Bank B 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 Aux Button 4 Bank B 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 1 6 Assigns Pump Number Pump 1 Pump 2 etc b Blower g Spa Light F Fiber...

Page 12: ...A b C d E F g H J L n o P r Filter 2 Start Hour Set 1 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r Filter 2 Duration Set 1 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r Standard Defaults 0 0 12 a...

Page 13: ...ycle runs If 4d is set to 0 only the Day cycle runs If neither 3d nor 4d is set to 0 both the Day and Night cycles run Sets default for user preferences only applies when persistent memory is reset A1...

Page 14: ...1 2 5 4 4 5 2 3 6 7 8 DOLPHIN REMOTE ROUND REMOTE Remote Button 1 Bank B 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 Remote Button 2 Bank B 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 Remote B...

Page 15: ...4 8 7 6 5 Time Warm Warm Mode e Cool ML90x Custom Buttons Enable n Y n Disabled Y Enabled 1 DIP Switch ML75x MX75x Custom Button 1 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 ML75x MX75x Custom Bu...

Page 16: ...L55x Custom Button 1 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 ML55x Custom Button 2 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 ML55x Custom Button 3 1 2 3 4 5 6 b g F E o t d P n A U r O H...

Page 17: ...Blower off when 2nd high speed pump on Note DIP A11 must be ON to use Special Amperage Rule Heat Cool Feature n Y n Disabled Y Enabled 1 DIP Switch Color Kinetics n Y n Disabled Y Enabled ACD n Y n D...

Page 18: ...The EL circuit board is factory configured to deliver a preset voltage 120V or 240V to the on board ozone connector J4 See the ratings table on the wiring diagram attached to the cover of the enclosur...

Page 19: ...ts 1 Jets 4 Jets 3 Jets 1 Jets 2 Jets 4 AX10A3 Optional on Se Jets 1 Jets 1 Blower Blower Jets 3 Jets 1 Invert Fiber Jets 3 Time Warm Jets 1 Jets 2 Jets 3 Cool Mode Prog Invert Fiber Light F2 TL F1 PL...

Reviews: