background image

B

L

3

4

,4

5

,4

5

B

R

1

B

K

2

W

T

1

1

B

K

2

WT11

N

N

B

R

1

L3

L2

L1

BR54

L1

BL34,4

5,45

(B

L

5

3

)

(B

L

5

3

)

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

BL34

BL35

BR39

BK12

BL52

BL52

BL52

BL52

BL33

BL32

WT42

BK40

B

K

2

BR41

B

R

1

B

L

3

1

1012-124

ELECTRICAL WIRING DIAGRAM & TABLES

P-SERIES  - 2 CHAMBER - 3 PH - 4 W - STAR 

MODESCO

00-10-11

UNLESS OTHERWISE NOTED, TOLERANCES ARE:

3 DEC.(.000):              .015"
FRACTIONS:              1/32"
BEND ANGLES             1

SCALE:

AP BY:

DR BY:

DATE:

DRAWING NO.

REV.

+-

+-

+-

BAKERS PRIDE

N.T.S.

.

.

L3

L2

12.6

  9.3

  9.3

  9.3

12.6

12.6

  6.3

  0.0

12.6

  0.0

AMPERE - W. LIGHT

L1

L3

10.0

10.0

9.9

9.7

12.6

  9.3

  9.3

  9.3

9.7

12.6

.

.

.

.

APP'D

BY

DATE

DESCRIPTION OF CHANGE

REV.

WATT PER HEATING COIL  &  TOTAL WATT PER UNIT

COIL LOCATION

MODEL NO: DP2

UC - UPPER CTR

UT - UPPER TOP

UB - UPPER BOTT

LT - LOWER TOP

LC - LOWER CTR

LB - LOWER BOTT

TOTAL NO LIGHT

TOTAL W. LIGHT

1,075

- - -

1,450

1,075

- - -

1,450

5,050

5,080

P48S

1,075

- - -

1,075

1,075

- - -

1,075

4,300

4,330

P46S

1,075

1,450

1,075

1,075

- - -

1,075

5,750

5,795

P44S

1,075

1,450

1,075

1,075

1,450

1,075

7,200

7,260

P44SH

1,075

1,450

1,450

1,075

1,450

1,450

7,950

8,010

VOLT A/C

AMPERE - NO LIGHT

230/400

UNIT

COILS L1

L2

230

9.3

MODEL

DP2

  0.0

P48S

230/400

230

9.3

P46S

230/400

230

9.3

P44S

230/400

230

9.3

P44SH

230/400

230

9.3

  0.0

  6.3

12.6

12.6

N

N

34.6

230

230

31.3

230

230

25.0

230

230

18.7

230

230

22.0

230

230

22.3

19.0

25.5

32.0

35.3

3.3

- - -

3.0

3.3

3.3

22.0

18.7

25.0

31.3

34.6

2.9

0.4

3.6

3.3

2.6

22.3

19.0

25.5

32.0

35.3

BL35

TERMINAL
BLOCK
1 PHASE

B

K

1

6

B

R

1

B

K

2

W

T

1

1

BK4

ELECTRONIC
TIMER  250V
      (OPT)

BL35
BK18

BL35
BK18

2 3 5 6

2 3 5 6

B

K

1

6

BL35

B

K

 2

6

B

K

2

0

BK16

BK18

BK18

BK28

B

L

3

6

B

R

3

9

W

T

2

4

W

T

1

3

B

R

3

7

BK28

(230V          1)

400V          3N

TERMINAL
BLOCK
3 PHASE

LOWER HEATING COILS

UPPER HEATING COILS

LB

LC

LT

UT

UC

UB

THERMOSTAT
  EGO 3 POLE

THERMOSTAT
 EGO 3 POLE

 CIRCUIT
BREAKER

 CIRCUIT
BREAKER

PILOT
LIGHT

PILOT
LIGHT

LIGHT
SWITCH
(OPT)

   LIGHT
SWITCH
    (OPT)

B

U

Z

Z

E

R

B

U

Z

Z

E

R

T

IM

E

R

 2

5

0

V

T

IM

E

R

 2

5

0

V

  LOWER
    BAKE
CHAMBER

  UPPER
    BAKE
CHAMBER

B

K

1

2

B

K

8

B

K

1

6

ELECTRONIC
TIMER  250V
      (OPT)

     ROBERTSHAW
    THERMOSTATS
1 OR 2 AS REQUIRED

BK2

BR1

WT13

WT24

BR37

BK8

B

L

3

6

2

3

 O

R

 4

 A

S

 R

E

Q

U

IR

E

D

2

5

0

V

 L

A

M

P

S

 (

O

P

T

)

9

All manuals and user guides at all-guides.com

Summary of Contents for PX-14

Page 1: ...ation adjustment alteration service or maintenance can cause property damage injury or death Read the Installation Operating and Maintenance Instructions thoroughly before installing or servicing this...

Page 2: ...irements for Installation 3 4 Initial Start Up 4 OPERATING INSTRUCTIONS SECTION ITEM PAGE 1 General Baking 5 2 General Baking Tips 5 3 Special Features 6 4 Cleaning 6 5 Service and Trouble Shooting 7...

Page 3: ...s only rated at 90 C If a line cord is used for the installation of the unit in Europe it should be a minimum of H07RN F type conforming to EN60 335 1 and or local codes Use minimum conductor size as...

Page 4: ...ate smoke or fumes and must be done in a well ventilated area CAUTION OVEREXPOSURE TO SMOKE OR FUMES MAY CAUSE NAUSEA AND DIZZINESS For initial heating of the new oven follow the steps below Place the...

Page 5: ...he cheese bubbles and the bottoms are evenly brown Rotate if necessary The design of the PX 14 and PX 16 is such that normal baking temperature may be too high for good results Set the thermostat appr...

Page 6: ...bake ovens Optional Electronic Timer A Digital electronic 99 minute timer can be provided on all models to give an audible signal at the end of a pre set time Note TIMER DOES NOT CONTROL THE OVEN For...

Page 7: ...the oven still does not operate take the following steps Disconnect the power supply to the unit by removing the supply cord and or turning off the main switch b Contact the factory factory representa...

Page 8: ...UPPER HEATING COILS LB LC LT UT UC UB L2 L1 THERMOSTAT EGO 3 POLE THERMOSTAT EGO 3 POLE CIRCUIT BREAKER CIRCUIT BREAKER PILOT LIGHT PILOT LIGHT LIGHT SWITCH OPT LIGHT SWITCH OPT 2 3 OR 4 AS REQUIRED...

Page 9: ...L1 L2 230 9 3 MODEL DP2 0 0 P48S 230 400 230 9 3 P46S 230 400 230 9 3 P44S 230 400 230 9 3 P44SH 230 400 230 9 3 0 0 6 3 12 6 12 6 34 6 230 230 31 3 230 230 25 0 230 230 18 7 230 230 22 0 230 230 2 1...

Page 10: ...T ELECTRONIC TIMER 250V OPT BK16 TIMER 250V BUZZER 250V LAMPS OPT 1 OR 2 AS REQUIRED LIGHT SWITCH OPT PILOT LIGHT CIRCUIT BREAKER CIRCUIT BREAKER THERMOSTAT EGO 3 POLE TE CE BE HEATING COILS BK28 BK18...

Page 11: ...MPS OPT BUZZER TIMER 250V BR7 BK16 ELECTRONIC TIMER 250V OPT ROBERTSHAW THERMOSTAT SINGLE POLE WITH SWITCH BR1 WT22 WT24 BR5 BK18 850 850 1 700 1 715 6 1 5 1 6 2 6 2 6 1 6 1 19 2 17 4 10 4 13 9 19 5 2...

Page 12: ...R LOWER CHAMBER LS LS L L LS LS L L UB UC UT TH P LB LC LT TH TH TH P 200V 1 200V 3 208V 1 208V 3 240V 1 240V 3 T LS B M L L LB LC LT TH TH P TH TH N 400V 3 N L1 L2 L3 P L L M B TH TH UT UC UB LS T TH...