background image

 CO11-G

      Full Size Gas Convection Oven

30 Pine Street • New Rochelle • New York • 10801

914 / 576 - 0200
914 / 576 - 0605

1 - 800 - 431 - 2745

www.bakerspride.com

fax
US & Canada
web address

BAKERS

PRIDE

16

            Exterior / Interior / Controls / Doors

Item     Part #     Description                                                Item     Part #     Description

Conversion Kit (Natural to LP)

Conversion Kit (LP to Natural)

1

E3450X

Door Seal, Top or Bottom, each (2)

49

P6007X

Elec Line Cord, 250V (UK)

2

E3451K

Door Seal, Sides, each (2)

50

N5048P

Rear Pipe Connection

3

E3466U

Door Closure Strip

51

P1144X

Snap-In Light Assy (w/130V Bulb)

4

S1317U

Door Handle

52

P1145X

Snap-In Light Assy (w/240V Bulb)

5

Q1477A

Screw, FH 10-32x1/2 (4)

53

P1146X

Light Bulb (15W, 130V)

6

Q3047A

#10 Lockwasher, Countersunk, Ext. (4)

54

P1147X

Light Bulb (15W,240V)

7

E3487X

Vertical Trim

55

P1082A

Conduit BX, 3/8"

8

E3485K

Outer Cover (Left)

56

P1084A

Bushing, Anti-Short, 3/8"

9

E3486K

Outer Cover (Right)

57

P1003X

Terminal Block (3 Pole)

10

E3501K

Outer Cover (Top)

58

M1049X

Switch, Momentary

 (Light &/or Steam)

11

E3499X

Access Cover (Side)

59

S1171A

Plug Button, 7/16"

12

E3488X

Top Trim

60

M1326X

Switch, Rotary (EGO)

13

E3583U

Bottom Apron

61

M1339A

Pilot Light Amber (Thermostat)

14

E3498X

Access Cover (Front)

62

M1340A

Pilot Light Green (Power)

15

S3203K

Latch Assy (Magnetic)

63

M1332X

Timer, 60 Minutes (120V)

16

E3514X

S/S Perforated Rear Panel

64

M1346X

Timer, 60 Minutes (208/240V)

17

E3454X

Door Assy Left (No Window)

65

M2138X

Ignition Control Module (24V)

18

E3458X

Door Assy Left (w/Window)

66

M1355A

Ignition Control Module, CE (24V)

19

E3456X

Door Assy Right (No Window)

67

M2139A

Harness w/Terminals

20

E3460X

Door Assy Right (w/Window)

68

M0110A

T-stat, G6, FAST (Domestic)

21

S3229A

Door Rod

69

M1553A

T-stat, E6, FAST (CE)

22

Q4033A

Roll Pin 1/4 x 1 1/4

70

M1555A

Probe, RTD Temp

23

S1048X

Window Assy

71

E3051K

Clamp, Temperature Sensor (1)

24

E3053K

Baffle Plate

72

P1042A

Victor Clip, Temp Sensor (3)

25

Q2009A

Thumb Screw, 1/4-20x1/2 (4)

73

M1176X

Potentiometer

26

E3095X

Baffle Plate Bracket Assy (4)

74

M1335X

Bell Audiolarm

27

Q1414A

Screw, Hex Hd, #10x3/4 (8)

75

S1311X

Knob (3)

28

E3481X

Combustion Chamber (Front Center)

76

M1352X

Ckt Breaker, 120-240V, 15A

29

E3482X

Combustion Chamber (Front Left)

77

30

E3511X

Combustion Chamber (Front Right)

78

M1356A

Solid State Relay, CE

31

E3471K

Door Switch Actuator

79

M1145X

Transformer (120V-24V)

32

M1102X

Microswitch (Rotary)

80

M1174X

Transformer (208/240V-24V)

33

81

M1157X

Motor, 1/4HP, 2Spd, 115V, 60

34

R3166A

Flue Adapter 7" (For Direct Venting Only)

82

M1217X

Motor, 1/4HP, 2Spd, 

200-230V,50-60

35

R3113A

Flue Diverter (For Direct Venting)

83

Q3008A

Flat Washer (4)

36

R3167A

Flue Diverter (For Collection Hood)

84

Q3014A

Lock Washer, Split (4)

37

U1043X

Bakers Pride Name Plate (13 3/4")

85

Q2204A

Nut, 5/16 HX, 5/16-18 (4)

38

U1290A

Control Panel Overlay (Rotary)

86

S1195X

Blower Wheel

39

U1437A

Control Panel Overlay (FAST)

87

Q2302A

Bolt, Wheel Puller 

3/8-16x2 Hx (2)

40

U1296A

Timer Overlay (50 cycle only)

88

P1108A

Conduit Connector,

 3/8"x1/2", 90 deg.

41

U1216A

Rating Plate

89

E3225X

Stacking Bracket, 

CO11-G2 Only

 

(Each)

42

U1055A

Caution Hot Label 

90

T3044A

Rack Support

43

U1128A

Supply Connection 

91

T3043A

Wire Rack

44

U1169A

Motor Rotation Arrow

92

E3483K

Flame Guard

45

U1210A

Installation Warning

93

E3531K

Door Limit Block

46

P6004X

Elec Line Cord, 115V (US & Can)

94

M1175X

Steam Timer, 115V

47

P6005X

Elec Line Cord, 250V (US & Can)

95

M1231A

Steam Timer, 208/240V (Export)

48

P6006X

Elec Line Cord, 250V (Europe)

4

R3175A

#57 Burner Orifice Spud, LP 

4

R3180A

#48 Burner Orifice Spud, Nat 

1

M1233X

LP Kit for Combination Valve 

1

M1343X

Natural Kit for Combination Valve 

1

R3160X

#78 Carry-over Orifice Hood, LP 

1

R3161X

#71 Carry-over Orifice Hood, Nat 

Page 3 of 4

                  

Note: When ordering, ALWAYS specify Part #, Model #, Serial #,Voltage/Phase & type of Gas.                

U6003A 8/07

         

  

Summary of Contents for Cyclone CO11-G

Page 1: ...ed area Overexposure to smoke or fumes may cause nausea or dizziness Note Only Pizza or Bread can have direct contact with ceramic decks All other food products must be placed in a pan or container to avoid direct contact with ceramic decks This equipment has been engineered to provide you with year round dependable service when used according to the instructions in this manual and standard commer...

Page 2: ... set of four 6 legs is supplied for stacked installations A carton containing a Flue Adapter and or an optional Draft Hood for Direct Venting Not available for European Community Countries B SET UP MOUNTING NOTE This appliance must be installed by competent person in accordance with the rules in force In the U K Corgi registered installers including the regions of British Gas undertake to work to ...

Page 3: ...olts 3 Insert Open Rack Shelf and tighten into place with eight 3 8 16 screws washers and nuts 4 Position Rack Supports and tighten in place using 4 each of Flat washers and 5 16 18 Hex Nuts To assemble over a Base Cabinet 1 Tilt cabinet over onto the left hand side Attach two mounting plates to the right underside and screw 6 legs into the center holes 2 Lift up left hand side of the base cabinet...

Page 4: ...e European Community countries should be as below GasType Supply Pressure G20 20 mbar G25 25 mbar G20 25 20 25 mbar G30 30 or 50 mbar depending on country G31 30 37 or 50 mbar depending on country A separate shut off valve for each oven must be provided It should be as close as possible to the place where the gas line goes into the oven It must be located such that it is easily accessible When sta...

Page 5: ...anges on the outside of the flue stack extending out of the building The flue pipe from the draft hood must not run downwards at any point from the oven to the final outlet It should always slant slightly upwards For best results it should rise straight up NOTE DO NOT PUT A DAMPER IN THE FLUE AND DO NOT CONNECT A BLOWER DIRECTLY TO THE FLUE If the flue runs directly to the free air outside the bui...

Page 6: ...n when done B TIMED COOKING ROTARYCONTROL I Close the oven doors 2 Turn Selector Switch to HI or LO position The indicator light near the Selector Switch will be illuminated 3 Turn the thermostat knob to the desired cooking temperature 4 Upon reaching the set temperature the indicator light near the thethermstat will go out 5 Load the oven with product to be cooked 6 Turn the timer knob to the des...

Page 7: ... NOT USE STEELWOOL Clean The Stainless Steel Interior Baked on splatter oil grease or discoloration on the stainless steel inside of the oven may be removed with stainless steel cleaner or any other similar cleaning agent NEVER use vinegar or any corrosive cleaner Use only cleaners approved for stainless steel NEVER use cleaning solvents with a hydrocarbon base NEVER use a wire brush steel or abra...

Page 8: ...8 wheel puller bolt supplied in center of hub See Fig 3 Clean The Porcelain Interior Porcelain enamel interiors are designed to be as maintenance free as possible However for best results the oven should be cleaned regularly Enameled interiors can be easily cleaned with oven cleaners KEEP CLEANING FLUIDS AWAY FROM ELECTRICAL WIRES LIGHT SOCKETS SWITCHES AND CONTROLPANEL OVEN EXTERIOR Clean The Ext...

Page 9: ... 2 13 x 1 HEX HEAD BOLT 12 REQUIRED 5 16 FLATWASHER 4 REQUIRED 5 16 18 HEX NUT 4 REQUIRED OPEN RACK SHELF RACK SUPPORT 3 8 16 x 3 4 TRUSS HEAD SCREW w NUT WASHER 8 REQUIRED 5 ILLUSTRATIONS CONTINUED CONTROL PANEL ROTARY CONTROL SELECTOR SWITCH PILOT LIGHT GREEN SELECTOR SWITCH THERMOSTAT PILOT LIGHT AMBER THERMOSTAT LIGHTS SWITCH TIMER STEAM INJECTION SWITCH Figure 3 Figure 4 Figure 5 9 ...

Page 10: ...re Check food a minimum number of times Lower oven temperature Use light shiny cookie sheet Use a cookie sheet not a baking pan Allow cookie sheet to cool between batches Set fan on low speed Lower temperature if using glass or dark pan lower 25 F 3 8 C Raise temperature Bake longer or raise oven temperature slightly Do not open doors to oven for long periods Reduce pan loads Thicken batter Lower ...

Page 11: ...O GC 20 NO COM L2 L1 NO NC ooox ooxo oxoo oxxo 24V 120V BUZZER TIMER M450 1 2 4 S Fan Rotary Switch Off Low High Cool Down Door Switch Solenoid Valve Amber Pilot Light Thermostat Green Pilot Light Temperature Controller Power RAM CO Power Timer Coil Steam Potentiometer Factory Set 8 Seconds Coil Steam Button Ignition Module Valve 2 Speed Motor Interior Lights Momentary Switch Interior Lights 11 ...

Page 12: ...me sensor ground valve hot thermostat L1 24vac ignitor 3 4 5 6 2 1 7 steam switch steam timer potentiometer blk yel red blu solenoid valve FF PILOT IN 120v 24v ignitor 120VAC 1 2 3 4 S Rotary Switch Door Switch Pilot Light Thermostat Pilot Light Power RAM LO HI COM 7 CO11 G WIRING DIAGRAM ROTARY CONTROL 12 ...

Page 13: ...sor L1 Ignitor Sensor RAM COM HI LO Door Sw NC NO Lights Switch CO VALVE 120 V Grn Ylo CH 100 FAST T12 T6 T7 T13 T9 T8 T5 T4 T3 T2 24V 120V T11 T10 RTD Probe Rotary Switch P2 P3 P4 P1 1 2 3 4 Closed Open 120 V L1 N BLK 1 WT 2 BLK 11 BLK 3 BLK 5 WT C2 WT 4 BLK S WT S2 WT S1 GREY 7 8 R1 R2 Orange Black A B BLK 13 BLUE 10 BLK C1 BLK 23 BLK 15 GREY 26 27 BLK 17 BLUE 12 BLK WT BLK 21 BLK 19 BRWN BRWN W...

Page 14: ... Natural 11 E3148X Top Right Angle Open Rack Stand 33 R3179P Combination Valve CE LP 12 E3149X Top Left Angle Open Rack Stand 34 R1116A Manifold 13 T3051X Left Rack Support Open Rack Stand 35 S3228A Flange Bearing 4 14 T3052X Right Rack Support Open Rack Stand 36 S3231X Door Chain Assy Complete 15 T8075X Bottom Shelf w Hdwr Open Rack Stand 37 S3226A Door Chain Rod Short 16 R3180A 48 Burner Orifice...

Page 15: ... 4 5 6 8 10 11 12 13 14 15 17 18 19 20 23 24 25 26 27 28 29 30 31 32 34 35 36 37 38 39 40 41 42 43 44 45 47 46 48 49 9 50 51 52 53 54 56 55 57 58 58 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 74 75 75 75 73 76 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 16 AK B ERS AK B ERS I R D P E I R D P E w S r i o tc o h D 93 21 21 22 22 7 7 Page 2 of 4 Note When ordering ALWAYS specify Part Model Serial ...

Page 16: ...K Clamp Temperature Sensor 1 24 E3053K Baffle Plate 72 P1042A Victor Clip Temp Sensor 3 25 Q2009A Thumb Screw 1 4 20x1 2 4 73 M1176X Potentiometer 26 E3095X Baffle Plate Bracket Assy 4 74 M1335X Bell Audiolarm 27 Q1414A Screw Hex Hd 10x3 4 8 75 S1311X Knob 3 28 E3481X Combustion Chamber Front Center 76 M1352X Ckt Breaker 120 240V 15A 29 E3482X Combustion Chamber Front Left 77 30 E3511X Combustion ...

Page 17: ...Notes 17 ...

Page 18: ...Notes 18 ...

Page 19: ...eriod of THREE MONTHS The installation of these replacement decks is the responsibility of the purchaser The extended Cyclone door warranty years 3 through 5 is a parts only warranty and does not include labor travel milage or any other charges EXCLUSIONS Negligence or acts of God Thermostat calibrations after 30 days from equipment installation date Air and Gas adjustments Light bulbs Glass doors...

Page 20: ...KERS PRIDE PRIDE BAKERS PRIDE OVEN CO INC 30 Pine Street New Rochelle NY 10801 1 914 576 0200 Phone 800 431 2745 US Canada 1 914 576 0605 Fax www bakerspride com WebAddress info bakerspride com e mailAddress 20 ...

Reviews: