background image

1  |  Baker Hughes

Copyright 2021 Baker Hughes Company. All rights reserved.

WARNING

BEFORE installing, using or carrying out any maintenance tasks associated with this instrument, 

READ THE INSTRUCTIONS CAREFULLY.

These instruments comply with the essential safety requirements of the European Directive ATEX 2014/34/EU.
It is certified to be used in Gas or Dust explosive atmospheres, groups IIC or IIIC:
•  Category II 1GD  – zones 0, 1, 2, 20, 21 and 22 for the protection mode “ia”
•  Category II 2GD  – zones 1, 2, 21 and 22 for the protection mode “db” and “tb”.

They also comply with the essential safety requirements of the European Directive EMC 2014/30/EU as 

amended, for use within an industrial environment.
It is the end user’s responsibility to:
•  Verify material compatibility with the application
•  Ensure proper use of fall protection when working at heights, per Safe Site Work Practices
•  Ensure use of proper Personal Protective Equipment
•  Take the appropriate actions to ensure that site personnel who are performing installation, commissioning 

and maintenance have been trained in proper site procedures for working with and around equipment, per 
Safe Site Work Practices

Products certified as explosion proof equipment MUST BE:
a)  Installed, put into service, used and maintained in compliance with European and/or national and local 

regulations and in accordance with the recommendations contained in the relevant standards concerning 

potentially explosive atmospheres.

b)  Used only in situations those comply with the certification conditions shown in this document and  

after verification of their compatibility with the zone of intended use and the permitted maximum  

ambient temperature.

c)  Installed, put into service and maintained by qualified and competent professionals who have been 

trained in proper site procedures for instrumentation used in areas with potentially explosive atmosphere 

and for working with and around equipment, per Safe Site Work Practices.

Under certain operating conditions, the use of damaged instruments could cause a degradation of the  

performances of the system which may lead to personal injury or death.
Use only genuine replacement parts, which are provided by the manufacturer, to guarantee that the products 

comply with the essential safety requirements of the European Directives mentioned above.

INSTRUMENT OPERATION

4700E/4800E apparatus: electro pneumatic positioner (force balanced principle) with integrated current to pressure 

converter (4000 I/P Converter). It controls the position of the plug of a control valve to a 4-20 mA control signal. 

Feedback is obtained by means of a cam.
4800E is a positioner with a high flow pneumatic block.

Summary of Contents for Masoneilan 4700E

Page 1: ...4700E 4800E Electropneumatic Positioners ATEX Instruction Manual Rev D Baker Hughes Data Classification Public...

Page 2: ...R REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN...

Page 3: ...rinsic Safety Entity Parameters 4 4 4 Conduit Entry in Flameproof Application 4 5 Assembly of 4700E or 4800E Positioner on a Valve 4 6 Pneumatic Connection of Positioner on a Valve 4 7 Installation an...

Page 4: ...to service used and maintained in compliance with European and or national and local regulations and in accordance with the recommendations contained in the relevant standards concerning potentially e...

Page 5: ...tability 0 5 0 5 Sensitivity 0 3 0 5 Conformity 1 1 Input impedance 170 ohms 170 ohms Maximum service temperature range refer to the marking on the apparatus Standard Instrument 40 C to 85 C 40 F to 1...

Page 6: ...and local regulations for electrical installation work Comply with national and local explosive atmosphere regulations Before carrying out any work on the device power off the instrument or make sure...

Page 7: ...e device power off the instrument or make sure that the local conditions in the potentially explosive atmosphere permit the safe opening of the cover Before switching on or after doing any work on the...

Page 8: ...in the potentially explosive atmosphere permit the safe opening of the cover Before switching on or after doing any work on the device always tighten the cover C with a seal J in good condition and pu...

Page 9: ...Masoneilan 4700E 4800E Positioners ATEX Instruction Manual 6 Copyright 2021 Baker Hughes Company All rights reserved...

Page 10: ...CIATED APPARATUS ANY SUITABLE SHUNT DIODE BARRIER OR GALVANIC ISOLATOR MEETING THE REQUIREMENTS IN NOTE 3 FOR T4 TEMP CLASS OR NOTE 4 FOR T6 TEMP CLASS MODEL 4000 CURRENT TO PRESSURE CONVERTER Ex ia I...

Page 11: ...Safety The cable entry must have a protection level at least equal to IP54 according to EN IEC 60529 standards For the housing with aluminum material the user will have to determine the use of the dev...

Page 12: ...rom the use of the information whether a claim is asserted in contract tort or otherwise Baker Hughes reserves the right to make changes in specifications and features shown herein or discontinue the...

Reviews: