© 2019 Baker Hughes Company. All rights reserved.
Masoneilan 12400 DLT ATEX Instruction Manual | 5
2. TYPE 12400 NUMBERING SYSTEM
12
4
a
b
—
c
d
Model
Action
Mounting
Protection
Housing
Material
4
-
HA
RT
c
ommunic
a
tion prot
oc
ol,
LC
D dis
pla
y
a
nd pus
h but
to
ns
,
S
IL c
e
rtifi
e
d
1
–
Controller
with adjustable
switches and
second 4-20 mA
analogue output
signal:
AO_1, AO_2,
DO_1, DO_2
2
–
Transmitter:
AO_1
3
–
Transmitter
with adjustable
switches and
second 4-20 mA
analogue output
signal:
AO_1, AO_2,
DO_1, DO_2
0
- Top and bottom,
Screwed, BW or SW
1 -
Top and bottom,
Flanged
2 -
Side and side,
Flanged
3 -
Top vessel,
Flanged
4 -
Side vessel,
Flanged
5 -
Top and side,
Screwed, BW or SW
6 -
Side and bottom,
Screwed, BW or SW
7 -
Side and bottom,
Flanged
8 -
Top and side,
Flanged
9 -
Side and side,
Screwed, BW or SW
1
-
FM & FMc
SI, NI, DIP, XP
and Nema 4X-6P
2
–
JIS
, Xproof
3
–
CU TR
,
IS, Xproof
and IP 66/67
4
–
INMETRO
,
IS, Xproof
5
-
ATEX & IECEx
IS, Xproof,
and IP 66/67
6
–
Other approvals
(based on ATEX
/ IECEx)
7
–
Other approvals
(not based on
ATEX / IECEx)
1
–
Aluminum with
epoxy painting
2
–
Stainless steel
Note: only the Transmitter function is SIL certified.
3. TECHNICAL SPECIFICATIONS
3.1. Performances
Refer to specific gravities between 0.15 and 1.4 with a standard displacer 907 cm
3
@ 1362 g.
➢
Accuracy:
± 0.5 %
➢
Hysteresis:
± 0.3 %
➢
Repeatability: ± 0.2 %
➢
Dead zone:
± 0.1 %
➢
Ambient temperature ranges:
In operation:
-50°C to +80°C
Storage and transport: -
50°C to +93°C
➢
Water ingress protection: IP66/67