background image

6  |  

Baker Hughes

© 2021 Baker Hughes Company. All rights reserved.

5. Mounting

Clean all the pipes before mounting the valve and completely remove dust, scale and other foreign 

matter. Mount the transfer valve as close to the actuator as possible and let air flow toward the IN and 

OUT marks located on the lower side of the body.

Two EXH ports are provided. Use one EXH port and put a blind plug in the other unused port. When 

using the valve as a lock-up valve, put a blind plug each in the two EXH ports.

Two air connection ports to the pilot part are provided on the 78-80H, one being marked SIG and the 

other, SIG OUT. Connect the signal pressure to the port marked SIG. Use SIG.OUT for sending signal 

to the 08-80H when it is also mounted.

The transfer valve functions to cut off IN and to connect OUT to EXH when the signal pressure lowers 

below the set pressure or is reduced to zero.

Do not use signal pressure at air pressure exceeding 1.03Mpa (10.5kgf/cm2).

Feeding signal pressure from near the IN side of the body will cause fluctuations in signal and air 

pressures due to the large air valve capacity. This may cause hunting.

6. Adjustment

The necessary settings of the transfer valve are generally performed at the factory and adjustment of 

it is not required. If, however, the setting pressure needs to be adjusted, make adjustment as follows:

a) Loosen the lock screw (26) and turn the adjust knob (17) counterclockwise to release the 

compression of the spring (25).

b) Turn the adjust knob (17) one or two turns clockwise to tighten it and to slightly compress the 

spring (25).

c)  Connect air pressure to “IN” marked on the body to check whether the body is open or closed. 

Then connect the pressure gauge and pressure reducing valve to the signal pressure connection port 

SIG.

d) Apply supply air pressure and set the air pressure to SIG at specified pressure by operating the 

pressure reducing valve while watching air pressure to SIG on the pressure gauge.

e) Turn the adjust knob (17) clockwise until air pressure no longer leaks through “OUT” marked on the 

body.

f)  This will cut off IN, and OUT and EXH will open in the transfer valve.

g) Lastly, fasten the lock screw (26) and fix it.

The ball (21) temporarily floats to transfer the pilot part and the valve emits a light beat tone 

when the set and signal pressures become the same. This is not an anomaly. The beating 

sound will stop when the transfer ends.

Summary of Contents for Masoneilan 08-80H

Page 1: ...Masoneilan Model 78 80H 08 80H Transfer Valves Instruction Manual Rev F Baker Hughes Data Classification Public ...

Page 2: ...R REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION OPERATION OR MAINTENANCE SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE CUSTOMER OPERATOR S PURPOSES...

Page 3: ...___________________ 5 2 Specifications_______________________________________ 5 3 Certifications________________________________________ 5 4 Numbering System___________________________________ 5 5 Mounting___________________________________________ 5 6 Adjustment_________________________________________ 6 7 Maintenance________________________________________ 6 ...

Page 4: ...te Indicates important facts and conditions About this Manual The information in this manual is subject to change without prior notice The information contained in this manual in whole or part shall not be transcribed or copied without Baker Hughes s written permission Please report any errors or questions about the information in this manual to your local supplier These instructions are written s...

Page 5: ...nd 9 2 Specifications Item Standard Option Maximum Operating Pressure Body 1 72 MPa Signal 1 03 MPa Set Pressure 100 700 kPa Hysteresis 34 kPa or less Cv Value IN OUT 4 5 OUT EXH 5 0 Connection IN OUT EXH Ports Rc1 2 NPT1 2 SIGNAL Port Rc1 4 NPT1 4 Operating Temperature Range 30 83 C 0 100 C Housing Material Aluminum Alloy 316L Stainless Steel 1 1 When the housing material is 316L stainless steels...

Page 6: ...e capacity This may cause hunting 6 Adjustment The necessary settings of the transfer valve are generally performed at the factory and adjustment of it is not required If however the setting pressure needs to be adjusted make adjustment as follows a Loosen the lock screw 26 and turn the adjust knob 17 counterclockwise to release the compression of the spring 25 b Turn the adjust knob 17 one or two...

Page 7: ...ty 1 Body AC 4B F CHROMATE 1 2 Housing ADC 12 CHROMATE 1 3 Plug SUS303 NBR 1 4 Piston A2017BE T6 CHROMATE NBR 1 7 Spring SUS304 WPB 1 8 O Ring NBR 1 9 O Ring NBR 1 10 O Ring NBR 1 11 O Ring NBR 1 13 Bottom Cap SUS303 1 14 Filter SUS304 2 16 Spring Case ADC12 CHROMATE 1 17 Adjust Knob VALOX420 1 18 Diaphragm Plate SUS303 1 19 Exhaust Orifice SUS303 1 20 Diaphragm NBR DUCRON 1 21 Ball SUS440C 1 22 A...

Page 8: ...ing Standard Specifications Part N Part Name Material Qty 1 Body AC2A F CHROMATE 1 2 Head Cap AC2A F CHROMATE 1 3 Plug SUS303 NBR 1 4 Piston A2017BE T6 CHROMATE NBR 1 5 Spring SUS304 WPB 1 6 O Ring NBR 1 7 O Ring NBR 1 8 O Ring NBR 1 9 O Ring NBR 1 10 Bottom Cap SUS303 1 11 Screw SUS304 4 12 Nut SUS304 4 ...

Page 9: ...Masoneilan 78 80H 08 80H Transfer Valves Instruction Manual 9 2021 Baker Hughes Company All rights reserved Notes ...

Page 10: ...s bakerhughes com Copyright 2021 Baker Hughes Company All rights reserved Baker Hughes provides this information on an as is basis for general information purposes Baker Hughes does not make any representation as to the accuracy or completeness of the information and makes no warranties of any kind specific implied or oral to the fullest extent permissible by law including those of merchantability...