background image

bakerhughes.com

151M7273 Revision - | English

Copyright 2020 Baker Hughes Company. This material contains one or more registered 

trademarks of Baker Hughes Company and its subsidiaries in one or more countries. All third-

party product and company names are trademarks of their respective holders.

Office Locations

Services and Support Locations

Headquarters

Australia

China

Leicester, UK

+44 (0) 116 2317233

[email protected]

North Sydney

1300 171 502

[email protected]

Beijing

+86 180 1929 3751

[email protected]

China

China

France

Guangzhou

+86 173 1081 7703

[email protected]

Shanghai

+86 135 6492 6586

[email protected]

Toulouse

+33 562 888 250

[email protected]

Germany

India

Italy

Frankfurt

+49 (0) 69-22222-973

[email protected]

Bangalore

+91 9986024426

[email protected]

Milan

+39 02 36 04 28 42

[email protected]

Japan

Netherlands

Russia

Tokyo

+81 3 6890 4538

[email protected]

Hoevelaken

+31 334678950

[email protected]

Moscow

+7 915 3161487

[email protected]

UAE

USA

Abu Dhabi

+971 528007351

[email protected]

Boston

1-800-833-9438

[email protected]

Tech Support

Brazil

China

Global

[email protected]

Campinas

+55 11 3958 0098, +55 19 2104 2983

[email protected]

Changzhou

+86 400 818 1099

[email protected]

France

India

Japan

Toulouse

+33 562 888 250

[email protected]

Pune

+91-2135-620421~425

[email protected]

Tokyo

+81 3 3531 8711

[email protected]

UAE

UK

USA

Abu Dhabi

+971 2 4079381

[email protected]

Leicester

+44 (0) 116 2317107

[email protected]

Billerica

+1 (281) 542-3650

[email protected]

Tel. +43 316 40 28 05 | Fax +43 316 40 25 06  |  nbn @ nbn. at | www. nbn. at 

Riesstraße 146, 8010 Graz

nbn Austria GmbH

Aufgrund laufender Weiterentwicklungen sind Änderungen der Spezifikationen vorbehalten.  Alle Angaben vorbehaltlich Satz- und Druckfehler.

Summary of Contents for Druck ADROIT6000

Page 1: ...Druck com ADROIT6000 Pressure Sensor Instruction Manual nbn Austria GmbH...

Page 2: ......

Page 3: ...try of manufacture 2 Description 2 1 Purpose ADROIT6 pressure sensors hereinafter referred to as sensors are designed for continuous measurement and conversion of gauge atmospheric absolute and differ...

Page 4: ...d using the sensor This includes all local safety procedures and installation standards this document and the product datasheet or specification drawing To identify the electrical and pressure connect...

Page 5: ...recommended to install sensors in front of the shut off device if the medium to be measured is liquid If water hammer exists in the system it is recommended to install a hydraulic shock dampener Atta...

Page 6: ...n use The sensors are calibrated during manufacture in the orientation pressure connector down and with the supply voltage at 15 V Supply voltage sensitivity is less than 0 005 FS V To adjust the Zero...

Page 7: ...T6000 Instruction Manual 5 3 7 2 App Use Once the sensor is connected as shown follow the on screen instructions to adjust the ADROIT6 Please note that you will only be able to recalibrate up to 5 of...

Page 8: ...uction Manual English 4 Key Documents A calibration certificate will have been shipped with your ADROIT6 pressure sensor The calibration certificate is printed exclusively in English Please find attac...

Page 9: ...y Requirements Supply Voltage Output Signal Electrical Connection Wiring Details ve Supply ve Supply Case Room Temperature Calibration Pressure Measured Permitted bar a Deviation Deviation Performance...

Page 10: ...Copyright 2020 Baker Hughes Company 8 ADROIT6000 Instruction Manual English...

Page 11: ...Copyright 2020 Baker Hughes Company English ADROIT6000 Instruction Manual 9...

Page 12: ...es com Japan Netherlands Russia Tokyo 81 3 6890 4538 gesitj bakerhughes com Hoevelaken 31 334678950 nl sensing sales bakerhughes com Moscow 7 915 3161487 aleksey khamov bakerhughes com UAE USA Abu Dha...

Reviews: