BAK Thermoplastic Welding Technology AG
3
Stop operating the automatic welding machine if:
- connecting line or plug have been damaged
- safety installations have been damaged
- changes occur in the operating state
EXTENSION CORDS
When using extension cords the minimum diameter of cables must be observed.
Extension cords must be approved and marked for their place of utilisation.
Before operating the machine examine the tool adjustment.
Proceed with adjustments only in cold condition (burn danger!).
NOZZLE ADJUSTMENT
-
Changes of the nozzle adjustments can be done if screws are loosened
-
For recommended settings use the following sketch
2,
5
42 -45
GUIDE ROLLER ADJUSTMENT
-
Bring the automatic welding machine into the welding position.
-
Push the transport roller to the right in welding position, take care that the spring sheet
engages.
-
Push the guide roller downward and fix it with the hexagon nut on the threaded bar.
Outside edge of the overlap, outside edge of pressure roll and outside edge of guide roller
must form a line.
(see following sketch).