BAK Thermoplastic Welding Technology AG
4
START UP OF THE AUTOMATIC WELDING MACHINE
Observe the section concerning safety of these operating instructions.
Before connecting the tool to the mains supply please check that:
-
Main switch is on pos. 0 OFF
-
Drive switch is on pos. 0
-
Heating switch is on pos. 0
-
Potentiometer of the air flow is on pos. 0 (100%)
-
The hot air blower is on pos. stand by (lifted up)
-
Put the plug into the socket
-
Put the main switch on pos. 01
The tool now heats up to the last selected set temperature.
To change the set temperature, check the section of the controller adjustment.
CONTROLLER ADJUSTMENT
Select on the potentiometer the desired welding speed.
On switching position ON the drive starts immediately and is constantly running.
On switching position AUTO the drive starts only after sliding the nozzle into the welding
seam and stops immediately after taking out the nozzle.
To separate the automatic welding machine from the electric system, change the main switch
to “OFF” und unplug the mains plug.
GUARANTEE AND LIABIITY
For BAK guarantee and liability see the general and sales condition on the back of the invoice
paper.
For the neglect or for damages resulting from it, the manufacturer / supplier will not accept
any liability.
Any utilisation of the automatic welding machine, for other purposes than those for which it is
intended, is subject to the consent of the manufacturer / supplier.
No warranty claims will be accepted if the automatic welding machine has been modified
unless this has been done in consultation with the manufacturer / supplier.
Actual temperature
Upward button
Downward button
Temperature
unit
Set temperature