DO’s:

  

 

1.

 

Do fully charge the PowerTop before using it for the first time. 

 

2.

 

Do charge the battery immediately if the warning alarm comes on. The warning comes on at 11.5 
Volts. It is good practice not to let the battery remain below 12 Volts without recharging.  

 

3.

 

Do keep the PowerTop fully charged to maintain battery at optimum capacity. Repeated deep cycling 
(deeply discharging the battery) reduces battery life. Where practical, plug the PowerTop to the mains 
or other power supply to keep the battery fully charged.  

 

4.

 

Do disconnect all the loads and remove the connections to Blue and Red Anderson connectors while 
using the AC internal charger.  

 

5.

 

Do use the maximum recommended DC-DC charger rated at 20A.  

 

6.

 

Solar charging - regulated charging through Grey Anderson plug and unregulated charging through 
Red Anderson plug. DC ON/ OFF switch must be ON while charging from Solar.  

 

7.

 

Do follow the ratings and connections for Solar charging as mentioned in page 7.  

 

8.

 

Do charge in a well-ventilated location. 

 

9.

 

Do make sure the PowerTop is kept in an upright position. 

 

10.

 

Do keep it away from sources of fire and high temperature. 

 

11.

 

Do avoid contact and submersion in water. 

 

12.

 

Do secure and fix the PowerTop before any off-road adventure.  

 

DONT’s:  

 

1.

 

DON’T connect any load while charging through internal AC charger, it 

is only a 6.6A charger.  

 

2.

 

DON’T use high capacity DC

-DC charger beyond the recommended charging current (max 20A).  

 

3.

 

DON’T go beyond the recommended load for each socket as mentioned in page 10.  

 

4.

 

DON’T open the unit, it will void the warranty. 

 

5.

 

DON’T block air vents of the PowerTop 

 

6.

 

This appliance is not intended for use by young children, or infirm persons with reduced or impaired 
mental or physical capabilities, or persons with a lack of knowledge and experience unless directly 
under the supervision or instruction of a responsible party to ensure that safe use conditions are met. 

7.

 

Damaged electrical cords are a hazard, in the case of damaged or frayed electrical cord DON

T use and 

seek replacement from the supplier. 

8.

 

DON

T Recharge non-rechargeable batteries.   

  

  

 

Summary of Contents for PowerTop V3

Page 1: ......

Page 2: ...n 7 If the appliance is not working as it should is damaged or has been dropped submerged in water or exposed to the elements for an extended period of time discontinue use immediately and contact suppliers Customer Service 8 Do not disassemble Contact suppliers Customer Service when service or repair is required 9 Do not stretch or place electrical cables under strain Avoid placing cable where it...

Page 3: ...PowerTop V3 User Operation Manual ...

Page 4: ...PowerTop V3 User Operation Manual ...

Page 5: ...PowerTop V3 User Operation Manual ...

Page 6: ...uire faster charging we recommend using a 20A maximum charger suited for Gel batteries with the following voltage set points Bulk 14 2V Float 13 7V The external charger is to be connected to the Grey Anderson connector labelled 50A Battery Output ...

Page 7: ...PowerTop V3 User Operation Manual ...

Page 8: ...harging source that is unregulated for example a 12V PV panel 36 Cell without a regulator it must be connected to the Red Anderson Connector input labelled Solar External Charge IMPORTANT NOTE DC On Off Switch must be ON for charging see page 3 for switch location ...

Page 9: ...e requirements connect the device to the Grey Anderson connector labelled 50A Battery Output Vehicle Charging IMPORTANT NOTE DC On Off Switch must be ON for charging see page 3 for switch location If you want to charge the PowerTop from the vehicle alternator connect a cable to the starter battery connect the other end of the cable to the Blue Anderson Plug on the PowerTop labelled Vehicle charge ...

Page 10: ...at the battery is being charged via the Solar Ext RED Anderson and Vehicle Blue Anderson inputs or on an AC charger The Boost cut out voltage is 14 2V and will cut in when the battery voltage drops below 12 7V FLOAT BATTERY LED will switch on when the BOOST cut out voltage is reached and will switch off when the Boost cut in voltage is reached The Float LED indicates the battery is not being charg...

Page 11: ...mmended load as a guide is under 500W dependent on ambient temperature Loads can also be connected to the following 12V DC Power sockets Ciga x 2 Maximum load Socket 10A Engel x 2 Maximum load Socket 10A USB x 2 Maximum load Socket 5V 2 3A Sockets output are protected by a 20A self resettable thermal breaker Maximum recommended load across all sockets as a guide is 200W dependent on ambient temper...

Page 12: ...unregulated o Blue Vehicle Charge Input connection o Grey Load connection to and from battery Protected by 50A thermal self resettable breaker Can be used for external higher power regulated output from a AC charger DC DC charger or solar charger to charge the battery Specifications Battery Type 12V 100Ah Sealed Lead Acid Battery In Built Battery Charger Mains input voltage DC output voltage 6 6A ...

Page 13: ...olar charging as mentioned in page 7 8 Do charge in a well ventilated location 9 Do make sure the PowerTop is kept in an upright position 10 Do keep it away from sources of fire and high temperature 11 Do avoid contact and submersion in water 12 Do secure and fix the PowerTop before any off road adventure DONT s 1 DON T connect any load while charging through internal AC charger it is only a 6 6A ...

Page 14: ...e Anderson plug with a DC DC charger such as CTEK D250S Dual The car smart alternator will be connected to the solar input not alternator input of the D250S Dual through a change over relay and the output of D250S Dual is connected to the Grey Anderson plug of the PowerTop The relay will ensure the charging is stopped as soon as the vehicle ignition is turned off so that the car battery does not g...

Reviews: