![background image](http://html.mh-extra.com/html/bailey/approach-advance-615-2017/approach-advance-615-2017_owners-manual_467142065.webp)
63
TR
UMA S
OLAR DU
AL B
A
TTER
Y CHAR
GER
Technical data
* Double the values of the 12 V – to work out the 24 V values.
Electrical values
Operating voltage Automatic recognition
12V
24V
max. input voltage
30V
50V
Voltage range*
8 - 15V
Allowed ambient temperature range
-35 °C – +55 °C
Allowed storage temperature range
-35 °C – +80 °C
Self-consumption
4 mA at night 10 mA during charging
PWM frequency, settable
25 Hz, 50 Hz, 100 Hz
Currents
SDC 10
SDC 20
max. module current constant at 25
°C
10 A (approx.
150 Wp)
20 A (approx.
300 Wp)
max. output current constant at 25 °C 10 A
20 A
Battery capacity
50 – 100 Ah
50 – 200 Ah
Charging voltage
Battery type, settable
Gel
AGM
Liquid
Absorbtion phase *
14,2 V
14,4 V
14,6 V
Float phase *
13,8 V
13,8 V
13,8 V
Equalisation charging phase *
14,6 V
14,8 V
Bulk phase reconnection
voltage *
13,3 V
Maximum charging voltage *
16,6 V
Temperature compensation *
-30 mV / K
Temperature sensor (measuring range)
-40 °C – +125 °C
Mechanical values
SDC 10
SDC 20
Protection type
IP 30
Installation
Wall mounted
Weight
200 g
230 g
Connection terminals
4 mm
2
Dimensions L x W x H
154 x 76 x 37,5 mm
Humidity (not condensing)
95 %
Summary of Contents for Approach Advance 615 2017
Page 1: ...OWNER S MANUAL ...
Page 10: ......
Page 25: ......
Page 33: ......
Page 59: ......
Page 134: ......
Page 140: ......
Page 162: ......
Page 176: ...SERVICE MANUAL ...
Page 177: ......
Page 179: ...Motorhome Overview 4 ...
Page 187: ...12 ...
Page 188: ...13 ...