24. Now, the sensors can be connected to the digital readouts. The
radial sensor needs to be connected to the radial digital readout,
and the linear sensor needs to be connected to the linear digital
readout. Batteries can also be installed if not already done so.
25. The excess wire can be coiled and zip tied. The linear sensor
wire should be secured to the sensor block to avoid getting
caught in the V-roller.
26. The digital readouts are preprogrammed from our factory. Notice
how the radial readout displays 360 degrees, and the linear
readout will display the position linearly up to the length of the
index table.
27. The buttons are as follows:
a. P – navigate between parameters
b. Left & Right arrows – choose within parameters
c. Star (*) – Select
28. The parts taken off are shown in Fig. 15.
(Fig. 14)
(Fig. 15)
Summary of Contents for IDX-10
Page 18: ...16 16 INDEX TABLE LAYOUT DIAGRAM...
Page 21: ...19 19 Diagram 1...
Page 22: ...20 20 Diagram 2...
Page 30: ...28 28 PARTS DIAGRAM Dog Leg Assembly Parts Diagram...
Page 31: ...29 29 Stand Assembly Parts Diagram...
Page 32: ...30 30 Table Assembly Parts Diagram...
Page 33: ...31 31 Stop Pin Lever Assembly Parts Diagram...
Page 34: ...32 32 Chuck Assembly Parts Diagram...
Page 38: ...36 36 NOTES...
Page 39: ...37 37 NOTES...