14/22
Instruction manual
24V motor control device for flush box mounting - Version 1.1
w w w .b ai e r- g mb h .d e
6
Initial operation
6.1.2
Configuration switch
Switch
Description
OFF
ON
1
Deadman’s
control
Semi
automatic
Deadman’s
control
2
Motor type
Prometheus
XS/80/MT
Prometheus
XS/120/MT
3
Maximum speed
normal
reduced
4
Motor generation
XS-2
XS
Table 1 – DIP-switch
1.
Semiautomatic function /Deadman‘s control
When the semiautomatic function is active, the drive is active as long as no
obstruction is detected or the end position is not reached, even if the control
input is not active any more.
When the deadman’s control is active, the drive is active as long as no
obstruction is detected or the end position is not reached, but it stops instantly,
if the control input becomes inactive.
2.
Motor type
Set switch according to used motor.
3.
Maximum speed
Set this switch to ON, if the drive should run in reduced speed only.
4.
Motor generation
Set switch according to used motor.
ON
OFF
Summary of Contents for PROMETHEUS Series