24V 50VA Motor control box -
Version 1.0
Instruction Manual
11/20
5
Mounting and electrical connection
w w w .b ai e r- g mb h .d e
5.3
Electrical connection
C A U T I O N
Wrong installation
Damage of motor control box or external components.
Observe polarity of connections.
Inputs (Terminals 8, 9, 10, 14, 15) are potential free.
Disconnect main power and protect against power up.
For safety instructions refer to chapter 2.
Connect internal power supply to power line.
Connect motor (terminals 1 and 2)
Polarity determines direction of operation.
Connect encoder (optional, terminals 3, 4, 5, 6).
Connect potential free on-site actuator (terminals 7, 9, 10).
Connect appliances dependent on requirements.
Motor control box connected successfully.
Carrying out electrical
connections
Motor control box
terminals
Motor cable color
coding