Copyright 1999-2009, Barcode Automation, inc.
20
Barcode Label Format Commands
Site Code
Command:
SC
Purpose: Used in CB-6 label format only to set the site code that is
transmitted out the Wiegand port.
Options: [00]-4095
Example:
SC 57
Facility Code Shift
Command:
FCS
Purpose: Used in BAI-10 label format only to change a facility code
value on the barcode to a valid number that will be
transmitted out the Wiegand port. Up to 8 different facility
code values may be shifted to numbers between 0 and 255.
Options: ON, [OFF] FCS xxx>yyy
First turn the function on by typing
FCS ON
and hitting
<enter>, then
type
FCS
, a space, the barcode facility code (xxx), a “
>“
sign, the
desired facility code number for transmission (1-255), then the
<enter> key.
FCS 368>019
If a barcode with a facility code of 368 is read, the BA-440
will shift the facility code value to 019 and transmit the data
out all communication ports.
FCS 368>019 359>019
A barcode with facility code 368 or 359 will have the number
shifted to 019 and transmitted out all communication ports.