BA-440 DualBeam Barcode Reader Quickstart Guide Ver 5

12. Turn Reader On

Turn Main Power switch On (refer to illustration for location) . You 
will hear a short beep and the output relays click as the gold polygon 
begins to spin. Within 15 seconds the laser will turn on and the 
BA-440 will be ready to operate. Use the enclosed sample barcode 
or a decal from the site for testing.

Hold the decal as shown and pass it through the laser lines at least 
two feet away from the reader. A successful read results in a short 
beep from the BA-440 and data transmission out both the serial port 
and Wiegand port. Decal should read out to at least 6’ out from the
reader. 

NOTE: You must wait at least 1 second after a read before 

the BA-440 will read the same barcode decal again.

13. Test Wiegand output with Verifier

The BA-440-Verifier-Output for the model BA-440 reader includes a test tool for detecting valid 26 
bit Wiegand messages. The Verifier can be used when installed in a BA-440 reader or used as a 
handheld Wiegand message verifier.

      Terminal block for connections

      Test circuit ON/OFF switch

        Green LED

Red LED

       Yellow LED

ISO switch for Wiegand mode

Beeper switch 

Main Power switch  

Isolated Wiegand switch 

YES 

NO 

Summary of Contents for BA-440 DualBeam

Page 1: ...not matter which side of the road it is mounted on as long as the vehicle decals are on the same side Always place the reader and decals on the same side of the car Typical Installation Position Mount...

Page 2: ...ver with 1 8 blade Wire stripper 4 Unpack Reader Remove Decoder Module box Hardware and Accessories box and Reader Enclosure from the shipping box Take Reader Enclosure from bag and flip upside down R...

Page 3: ...6 Seal wiring port in Baseplate Once the wiring is run up the mounting post and out through the hole in the Baseplate you can use the 4 putty roll from the hardware bag to seal the opening in the bas...

Page 4: ...he gold polygon This gold polygon should face the road with the terminal block for connections at the rear of the Baseplate Use the four 5 16 nylock nuts on the threaded studs to secure the decoder mo...

Page 5: ...DC source 24V POWER INPUT Positive input from 24VDC source GdRead RELAY OUTPUT Gate normally open NO GdRead RELAY OUTPUT Gate normally open NO Aux In INPUT for Vehicle presence trigger Aux In INPUT fo...

Page 6: ...ly 5Vdc present on the Data0 and Data1 terminals If the voltage is present communications should operate fine 11 Convert to Direct Wiegand connection if Optoisolated connection does not function Direc...

Page 7: ...n a short beep from the BA 440 and data transmission out both the serial port and Wiegand port Decal should read out to at least 6 out from the reader NOTE You must wait at least 1 second after a read...

Page 8: ...ck the voltage on Data 0 and Data 1 to see if there is 5 VDC present If no voltage is found or if voltage is less than 3 Vdc Wiegand messages cannot be sent Be sure the access system is connected and...

Page 9: ...the test circuit is live for 10 minutes after you turn the test switch ON then it will go into hibernation This is to preserve battery life if the technician forgets to turn the test circuit off To re...