background image

9

www.stairslight.com

The relays used to separate 230V circuit from 

the controller may be of any type. We recommend 

the relays to be mounted on T-35 bus, the same as 

the controller. Their use helps with the installation.

Photo to the left shows our product STP-4811 — a 

set of two relays in a single-rail case T-35. This set 

makes it possible to separate 230 V voltage coming 

simultaneously from two motion sensors.

Installation diagram: 110-230V motion sensors connected to the controller

Set of two relays STP-4811

Summary of Contents for STX-1795

Page 1: ...of stairs and after some time fades them out smoothly The controller is adapted to control MONO LED strips mounted in stair steps or LED points spots built into the wall above the steps The LED strip controller can light up each step smoothly which gives a nice visual effect Lights can be turned on by directly pressing a button on the wall which is connected to the controller or by using an additi...

Page 2: ...umber of illuminated handrails 2 Supply voltage 12V Dimensions length 11cm width 9cm height 7 cm Mounting on T 35 rail the width of 6 modules Output capacity up to 5A per one output Running by short to ground negative power supply Functions buttons and control LED Description of buttons on the body UP button starts the animation towards the top DN button starts the animation towards the bottom MID...

Page 3: ...the LED lighting is connected should be checked carefully Similarly the animation after the button BOT is pressed should be checked in this case the stairs lighting should take place downwards It is recommended to adjust the sensor response to movements without connecting them to the inputs of the controller The sensor pulse time TIME must first be set to extreme minimum and it should not be chang...

Page 4: ...olored bands RGB there is the dedicated STX 1793 controller The standard supply voltage is 12V The controller can also be connected to 24 V LED strips but because of the controller electronics the voltage should not be exceeded Instalacja elektryczna stopni schodów taśmy LED Electrical installation LED strips LED strips are usually placed under the steps Points should be connected together and by ...

Page 5: ...owest level output 2 to the second higher etc The output 32 is connected looking from the bottom of the stairs to the right handrail running up and the output 31 to the left handrail running down All the points of LED strips should be con nected with each other and the value points should be connected to the outputs of the controller LED strips connected to the controller ...

Page 6: ...o the right handrail running up and output 24 to the left one running down Lamps generally have no polarity so you should just follow the rule that the lights should be connected with each other and with the plus value and the second pole of each lamp must be connected to the corresponding controller output If the staircase is smaller and there are no illuminated handrails you can use exit No 25 f...

Page 7: ... lights should have a much larger cross section than the cables between the controller and individual LED strips Installation must be carried out very carefully and securely to avoid loosening of wires or short circuits between them LED strip wires should be soldered We do not recommend using special sockets and plugs because after a while due to the movements of the stairs they become loose and m...

Page 8: ...m the controller inputs Low voltage sensors will almost certainly need a special adapter matching the sensor signal to requirements of the controller The following diagrams and descriptions explain how to connect the most common types of sensors If you need to use a different type of sensor please contact the manufacturer to establish how to connect the sensor We recommend that buttons such as doo...

Page 9: ...he same as the controller Their use helps with the installation Photo to the left shows our product STP 4811 a set of two relays in a single rail case T 35 This set makes it possible to separate 230 V voltage coming simultaneously from two motion sensors Installation diagram 110 230V motion sensors connected to the controller Set of two relays STP 4811 ...

Page 10: ... of the Fresnel lens sho uld be covered with an opaque material If the motion sensor does not have a built in light sensor at least a small steady source of light over the sensor should be added to light up the field observed by the sensor Assembly diagram of motion sensors CRN 5891 connected to the controller by a set of relays STP 4811 NOTE The knob Time in the sensors must be set to the minimum...

Page 11: ...ge of sensitivity adjustment as well as a removable bowl that can be screened to reduce the field of view It is equipped with a diode signaling the impulse of the sensor It can be powered from the same voltage 12V as LEDs Standard motion sensor 12V CRN 5481 The CRN 5481 sensor fits freely into a 60 mm mounting box Dimensions 32x24x18 mm The sensor has a wide range of sensitivity adjustment as well...

Page 12: ...n on the sensor connector It is recommended to use colored wires with a possibly small cross section eg a telephone cable harness Please note that any mistake in connecting wires especially power supplies can damage the sensor or controller To facilitate assembly to each sensor is added the connector to soldering The sensor s angle of view can be adjusted by gluing the sensor s bowl removed from t...

Page 13: ...13 www stairslight com Installation diagram 12V motion sensors connected to the controller ...

Page 14: ...ase mezzanine but so it does not react to people walking up the stairs After detecting a person entering the stairs to the mezzanine the controller will immediately start the lighting of the whole staircase and turn it off after approx 20 seconds The diagram on the neighboring side shows such a solution Mezzanine case Installation diagram shows connecting three motion sensors 12V to the controller...

Page 15: ...as follows setting each parameter is indicated by a rapid flickering of the green LED and first step If during this flickering the SET button is pressed and held then depending on the parameter you will see from one to several dozens of slow LED pulsees Setting the parameter takes place after a release of the button after the desired number of pulsees or just after the end of the flickering During...

Page 16: ...s from the bottom to the mezzanine To set the number of steps press and hold the SET button during the third flickering You should release the button after the right number of flicks Eg to set 8 steps release the button after 8th flick To re enable lighting up stairs upon entering mezzanine you must let go off the button immediately after the third flickering Flickering 4 Staircase backlight Steps...

Page 17: ...oportional to the time interval and is approximately 0 5 seconds per unit impulse This parameter is factory set to 0 minimum value which makes the next step is lightened immediately after the previous one Flickering 8 Time between illuminating and fading out the staircase It is a time in which after switching steps such as one by one they light up continuously at all levels before the start of the...

Page 18: ...long impulse often lasting dozens of seconds It can cause an incorrect operation of the controller eg a constant light In this case you can set a delayed start of the controller about 1 minute At that time after powering of the whole system the controller does not respond to the buttons or sensors This is indicated by the blinking of all steps Normally the delayed start function is on Releasing th...

Reviews: