17
www.stairslight.com
Marker – Fixed light – 2 sec.
Flickering 6 – Lighting of the steps.
You can set the time of a slow lighting of the steps. This gives an effect which is more than
pleasing than turning on a sharp light at full power. The factory setting is 10, which corresponds to
0.5 second time of single step illumination (a total of 10 seconds for 20 steps). Releasing the button
after the end of the flickering sets the time to the default value (approx. 0.5 sec. – 10 units). However,
if the button is held on, you can set a different, shorter or longer period of time for the illumination a
single step. The number of pulsees is proportional to the time of illumination. Just hold the button for
the appropriate number of pulsees (default setting of 10).
Flickering 7 – Time interval between lighting consecutive steps.
Releasing the button after the end of the flickering sets the time at the minimum, so that the
speed of the staircase lighting depends on the time of steps illumination. However, if the illumination
time (parameter 4) is set at a low or zero value (for example, when lamp lights are used), set the
value of the experimental time interval so that the steps will light up at the right speed. Number of
pulsees is proportional to the time interval and is approximately 0.5 seconds per unit (impulse). This
parameter is factory-set to 0 (minimum value), which makes the next step is lightened immediately
after the previous one.
Flickering 8 – Time between illuminating and fading out the staircase.
It is a time in which, after switching steps such as one by one, they light up continuously at all
levels, before the start of their fading out. Factory value is set to 10 seconds, which is equal to 10
impulses (1 impulse = 1 second).
Flickering 9 – Time of illumination for a second person.
If another person enters the staircase, the illumination of all steps will be turned on. It is measu-
red from zero at each entry of another person; the light will turn off after a set time measured from
the entry of the last person. This time is pre-set to 20 seconds, which equates to 20 impulses (1
impulse = 1 second).
Flickering 10 – Controller blockade time.
If the sensor detects more than one impulse, for example, due to the movement of other people
on the stairs, the controller can react by turning on the lights over all of the stairs, just like during the
entrance of another person. To avoid this, you can set the so-called blockade time counted from the
end of the first impulse, during which the controller will not respond to further impulses. Blockade
time is pre-set for 2 seconds, which corresponds to 2 impulses (1 impulse = 1 second).
Marker – Fixed light – 2 sec.