BaehrTec A2000 operating instructions
Page 34/58
English – V101 - effective 10/13
3
rd
filter cassette
The filter cassette includes several different fleeces with different
properties:
•
Sound-insulating fleece
This fleece ensures that the suction noise is reduced and thus contributes to the
comfortable volume of the A2000.
•
Coarse filter fleece
This fleece filters coarser particles from the extracted air
•
Carbon filter fleece
This fleece ensures that most odours are neutralised.
•
Ultra-fine filter fleece
This fleece filters ultra-fine particles from the extracted air.
However, this fleece is also responsible for filtering viruses and bacteria from the
extracted air (maximum separation rate 99.99 %).
•
Carbon filter foam
This fleece also ensures the neutralisation of odours.
For information on how to change the fleeces of the filter cassette, please refer to
the section
“Changing the filter cassette”
.
Before you change any of the filters, please turn off the device at the main
switch
(3)
and remove the safety plug
(58)
from the socket.
Used filters must not be cleaned and the dust bags must not be emptied
and then re-used. Always use fresh filters and a new dust bag for each
filter change.
Please put used filters in the residual waste. It is preferable to discard
this in a press-fastening bag.
4.9.1
Changing the dust bag
In principle, the dust bag must be changed immediately once the symbol for a dust bag
change
lights up on the display.
If the icon for a dust bag change lights up, the suction system will no longer be fully
powerful. If you do not heed this indication, the device will switch automatically
within 30 seconds back to suction level 3. This prevents the device from being
damaged.
To change the dust bag, please proceed as follows:
1) Turn off the device at the main switch and disconnect it from the power supply.
2) Disconnect the dust bag lid from the controller (see section
“Disconnecting/connecting
the dust bag lid to the controller”
).
3) Remove the old dust bag from the receptacle
(39).
4) Clean the filter chamber and the dust bag lid each time you change the dust bag in
order to guarantee proper suction power and to prevent germ formation. Think of your
health!