Programming
Page 36/51
MID_M2000_BA_02_1807
5.2.8 Language Select
Language select
The unit supports English along with one alternate language. The
alternate language choice is set at the factory.
PowerUp
Counter
The number of times that the unit has been powered on.
Power Off
Totalizer
The totalizer accumulates the time during which the device is switched
OFF.
This time can be reset by the function “Reset Totalizer -> Tpwroff“
Version info
The current software version of the unit.
Serial number
The manufacturing serial number of the installed electronics in the format
YYMM####.
Meter Tag Name
Customer tag name. Programmed via the interface modules.
Daughterboard
Info
Information about the plugged in interface board (HART, Profibus, etc.).
Polariztation
Voltage
Measure electrode polarizing voltage in ± V (just for service purpose)
Restore
Default
Restores all non-calibrated parameters to the factory defaults.