![Badger Meter ModMAG M1000 User Manual Download Page 4](http://html1.mh-extra.com/html/badger-meter/modmag-m1000/modmag-m1000_user-manual_3396567004.webp)
Verification Device
Page 2 / 23
MID_VD_BA_02_1607
2. Verification Device
2.1 Disclaimer
The user/purchaser is expected to read and understand the information provided in this
manual, follow any listed safety precautions and instructions and keep this manual with
the equipment for future reference.
The information in this manual has been carefully checked and is believed to be entirely
reliable and consistent with the product described. However, no responsibility is
assumed for inaccuracies, nor does Badger Meter assume any liability arising out of
the application and use of the equipment.
Should the equipment be used in a manner not specified by Badger Meter, the
protection provided by the equipment may be impaired.
2.2 Product identification information
Record the product identification numbers from the nameplate.
Modular Mag Meter
Model number M5000________________________________
Serial number ______________________________________
Tag number (if applicable)
2.3 Product description
Field Verification Device is a portable test device for the electromagnetic flow meters
type ModMAG
®
M1000, M2000 and B-MAG I M5000.
With the Field Verification Device, accurate verification of meter functionality is assured
without taking the meter out of the pipeline ("wet" test) and interrupting functionality.
Meter diagnosis and calibration can be performed on-site. A "dry" test (removing the
meter and benchtesting) can also be performed. The complete verification test
consumes approximately 20 minutes and results can be downloaded to a Microsoft
Windows
®
personal computer.
2.4 Functions
The Verification Device also:
•
determines if the meter is within one percent of the original factory
calibration.
• verifies the functionality of all of the meter's inputs and outputs.
• measures electrode resistance and integrity.
• measures coil resistance and integrity.
• measures coil insulation resistance.
• measures current and frequency at previously selected flow rate.
• evaluates the signal processing functionality.
•
verifies that there is no high-voltage noise disturbing the coil circuit.