INTRODUCTION
The Series 3100 Monitor is an economical, dual channel, full featured, digital rate and totalizing monitor, compete
with set-point control, scaled pulse output, analog outputs, analog PID controller, USB, and RS485 Modbus and
BACnet communication .
Panel mount is NEMA4X-rated, and conforms to DIN standard dimensions (96 mm x 96 mm) for meter size and panel cutout .
An optional NEMA 4 wall mount will be available in the future .
The back-lit, two-line by 16-character alphanumeric display can be configured by the user with factory preset or with
user-defined units of measure . Any combination of two rates or totals from either input channel can be displayed at any one
time, with the special feature of channel addition or subtraction . LEDs report relay status and digital communication .
Inputs are from any combination of two pulse, sine wave or linear analog input devices .
Configuration is menu driven using the LCD/keypad interface, or USB computer connection, with multiple password gates to
prevent unauthorized access, while allowing access to select features such as total and relay reset functions .
Outputs include four Form C mechanical relays, one solid-state switch, two Analog Outputs, one USB, and one RS-485 with
BACnet and Modbus protocols .
Advanced Standard Features
• Easy to switch power supplies from 12…24V AC/DC to the optional 120/240V AC .
• Nonvolatile memory; no battery backup is required .
• Two independent pulse and analog input channels can be used separately or combined in addition or subtraction modes,
for all display output functions .
• Field-definable custom units of measure labeling and conversion factors .
• Two line by 16-character 3/8” (7 .95mm) high back-lit display .
• Front panel LEDs indicate status of each relay, pulse output, and Rx/Tx activity .
• Simple front panel configuration with the option to use the USB port .
• USB communication is a very powerful diagnostic and OEM tool .
• Two level password protection; one to restrict setup access and one to protect totals .
• Field-definable custom units of measure labeling and conversion factors .
• A total of seven independent relay, pulse and analog outputs .
• Powerful set-point control, with independent set and release point values, set and release delays, and latching functions
• Scaled pulse output with pulse width control .
• Dual channel analog outputs are either current sinking or sourcing 4…20 mA or 0…20 mA . Current sourcing 0…20 mA
permits external conversion to 0…5V DC or 0…10V DC .
• PID process control using analog outputs .
• RS-485 with Modbus and BACnet/MSTP protocols .
• IIFR (Infinite impulse response filter) . Proprietary input signal smoothing .
3100 Series Ordering Matrix
Example: 3100
-
x
x
Series
Flow Monitor
3100
-
Power
Supply
Low Voltage
0
12…24V AC/VDC
High Voltage
1
120/240V AC
Mounting
Panel Mount
0
Figure 1: Ordering matrix
Introduction
Page 5
August 2014
CTL-UM-001026-EN-04
Summary of Contents for Impeller Data Industrial 3100 Series
Page 2: ...Data Industrial Series 3100 Dual Channel Monitor Controller Transmitter Page ii August 2014...
Page 14: ...Figure 15 Flow inputs Programming Page 14 August 2014 CTL UM 001026 EN 04...
Page 15: ...Figure 16 Relays pulse outputs Programming Page 15 August 2014 CTL UM 001026 EN 04...
Page 16: ...Figure 17 Analog inputs Programming Page 16 August 2014 CTL UM 001026 EN 04...
Page 17: ...Figure 18 RS 485 communication port Programming Page 17 August 2014 CTL UM 001026 EN 04...