Troubleshooting
TROUBLESHOOTING
RELIEVE THE PRESSURE PRIOR TO CHECKING OR REPAIRING THE METER. MAKE SURE ALL VALVES, CONTROLS AND
PUMPS ARE OPERATING CORRECTLY.
Symptom
Possible Cause
Remedy
Battery Icon is
displayed
Batteries are low
Replace batteries
Display Blank
Meter asleep
Press
RESET
Loose battery connection
• Remove battery pack and check battery connection
• Press
RESET
Batteries dead
• Replace batteries
• Press
RESET
Meter does not latch
for batching
Meter not in AUTO mode
Press
AUTO
and program the batch size
Meter not reset after prior batch
Press
RESET
Low batteries
• Check for battery icon
• Replace batteries
• Press
RESET
Slow or no fluid flow
Filter is clogged
Clean or replace the filter in the swivel nut
Pump pressure is low
Turn up the pump pressure
Foreign material is jamming meter Contact your local distributor for repair
Meter inaccurate
Scale Factor not correct for fluid
Enter
Program Mode
, check and reset the Scale Factor