Outdoor LP Gas Barbecue Grill
Model No. GBC1460W / BY14-101-01-04
14
Troubleshooting
Problem
Possible Cause
Prevention/Cure
Burner will not light using ignitor
LP gas tank valve is closed
Make sure regulator is securely attached to the LP gas tank per “Installing LP
Gas Tank,” then turn LP gas tank valve to “OPEN”
LP gas tank is low or empty
Exchange, refill or replace LP gas tank
LP gas
1. Turn LP gas tank valve to “CLOSED”
2. Wait 5 minutes for gas to clear
3. Follow “Checking for Leaks” section
Battery needs to be changed
Replace the “AA” battery (follow assembly step for inserting battery)
Wires or electrode covered with cooking residue
Clean wire and/or electrode with rubbing alcohol
Electrode and burners are wet
Wipe dry with cloth
Electrode cracked/broken - sparks at crack
Replace electrode
Wire loose or disconnected
Reconnect wire or replace electrode/wire assembly
Wire is shorting (sparking) between ignitor and electrode Replace ignitor wire/electrode assembly
Bad ignitor
Replace ignitor
Burner will not light with match
No gas flow
Check if LP gas tank is empty
A. If empty, exchange, refill or replace LP gas tank
B. If LP gas tank is not empty, refer to “Sudden drop in gas flow or reduced
flame height” (see below)
LP gas tank is low or empty
Exchange, refill or replace LP gas tank
LP gas
1. Turn LP gas tank valve to “CLOSED”
2. Wait 5 minutes for gas to clear
3. Follow “Checking for Leaks” section
Coupling nut and regulator not fully connected
Turn the coupling nut about one-half to three-quarters additional turn until solid
stop.
Tighten by hand only - do NOT use tools.
Obstruction of gas flow
1. Clear burner/venturi pipe
2. Check for bent or kinked hose
Disengagement of burner to valve
Reengage burner and valve
Spider webs or insect nest in venturi
Clean burner/venturi pipe
Burner ports clogged or blocked
Clean burner ports
Sudden drop in gas flow or reduced flame height
Out of gas
Exchange, refill or replace LP gas tank
Overfilling prevention device may have been activated
1. Turn control knobs to “ OFF”
2. Wait 30 seconds and light grill
3. If flames are still too low, reset the overfilling prevention device:
a. Turn control knob(s) “ OFF”
b. Turn LP gas tank valve to “CLOSED”
c. Disconnect regulator
d. Turn control knobs to (HIGH)
e. Wait 1 minute
f. Turn control knobs to “ OFF”
g. Reconnect regulator and leak check connections, being careful not to
fully open valve
h. Light grill per “Lighting” section
Irregular flame pattern, flame does not run the
full length of burner
Burner ports are clogged or blocked
Clean burner ports
Flame is yellow or orange
New burner may have residual manufacturing oils
Burn grill for 15 minutes on (HIGH) with the lid closed
Spider webs or insect nest in venturi
Clean venturi
Food residue, grease, etc. on burners
Clean burner
Poor alignment of valve to burner/venturi pipe
Ensure burner/venturi pipe is properly engaged with valve
Flame goes out
High or gusting winds
Do not use grill in high winds
Low on LP Gas
Exchange, refill or replace LP gas tank
Overfilling prevention device may have been activated
Refer to “Sudden drop in gas flow or reduced flame height” (see above)
Flare-up
Grease buildup
Remove and clean all grill parts per “Cleaning and Care” section
Excess fat in meat
Trim fat from meat before grilling
Excessive cooking temperature
Adjust to lower cooking temperature
Persistent grease fire
Grease trapped by food buildup around burner system
1. Turn control knobs to “ OFF”
2. Turn LP gas tank valve to “CLOSED”
3. Leave lid in closed position and let fire burn out
4. After grill cools, remove and clean all parts per “Cleaning and Care” section
Flashback (fire in burner tube(s))
Burner and/or burner/venturi pipe are blocked
Clean burners and/or burner/venturi pipe
Inside of lid is peeling (like paint peeling)
The lid is stainless steel, not painted
Grease buildup has turned to carbon and is flaking off – clean thoroughly per
“Cleaning and Care” section
The lid is coated/painted
• This can be from baked on grease buildup that has turned into carbon and is
flaking off
• Clean thoroughly per “Cleaning and Care” section
For more assistance, please visit us at BlueRhino.com or call 1.800.762.1142.