MGS-401 User Manual

 

 

 

8.

 

Parts Numbers and Service 

8.1

 

Part Numbers 

 

      Part # 

Description 

6702-8030 

MGS-401 Entrance Monitor 

6600-8950 

Sunshield for outdoor locations 

1100-8950 

Security Screws ((6) pcs. and driver bit) 

6900-0010 

>100dB External sounder (mounted in MGS-401 Cable Gland) 

www.mybacharach.com  MGS Family of Gas Detectors 

8.2

 

Service Center Locations 

Prior to shipping equipment to MSA Bacharach, visit www.mybacharach.com for a Returned 

Merchandise Authorization Number 

(RMA #)

. All returned goods must be accompanied by an RMA #. 

Pack the equipment securely 

(in its original packing, if possible)

, as MSA Bacharach cannot be held 

responsible for any damage incurred during shipping to our facility. 

 

Location 

Contact Information 

Shipping Address 

United States 

Phone: +1 724 334 5000 

Toll Free: +1 800 736 4666 

Fax: +1 724 334 5001 

Email[email protected] 

MSA Bacharach, Inc. 

621 Hunt Valley Circle 

New Kensington, PA 15068, USA 

ATTN: Service Department 

Europe 

Phone: +353 1 284 6388 

Fax: +353 1 284 6389 

Email[email protected] 

MSA Bacharach, Inc. 

Unit D12 & D13 Santry Business Park, Swords Road 

Santry, Dublin, Ireland 

ATTN: Service Department 

Canada 

Phone: +1 905 882 8985 

Fax: +1 905 882 8963 

Email[email protected] 

MSA Bacharach, Inc. 

10 West Pearce Street, Unit 4 

Richmond Hill, Ontario. L4B 1B6, Canada 

ATTN: Service Department 

 
 

 

 
 
 

 

 

 

Summary of Contents for MGS-401

Page 1: ...MGS 401 Entrance Monitor for Commercial Industrial Applications FixedGasDetection P N 1100 2527 Revision 1 0 User Manual...

Page 2: ...charach com SERVICE POLICY MSA Bacharach Inc maintains a service facility at the factory Some MSA Bacharach distributors agents may also have repairfacilities however MSA Bacharach assumes no liabilit...

Page 3: ...ts of this manual for important information on the operation and maintenance of the instrument 1 2 Conventions 1 2 1 Iconography Alert Icon Description WARNING Potentially hazardous situation which if...

Page 4: ...lications Make sure the device is not located in areas that contain a flammable mixture of gas and air Otherwise an explosion can occur The device is not intrinsically safe Do not use the device in ar...

Page 5: ...nce Monitor is but one piece of a complete gas detection system MGS 400 Series Gas detectors in the monitored area can signal via digital bus relays and or audible and visual output The digital Modbus...

Page 6: ...de 6560 ft 2000 M Communications RS485 Modbus RTU Client for Gas Detectors RS485 Modbus RTU Server for BMS Visual Audible Signals Integrated high output visual strobe Integrated high output audible al...

Page 7: ...er Manual 2 4 Front Panel Figure 2 4 Front Panel Layout Front Panel Description 1 Integrated visual alarm in bezel 2 Controller Power Fault LEDS 3 Mute alarm button 4 80dB Alarm 5 NPT Cable Glands x2...

Page 8: ...2 5 MGS 401 Under Lid Connections and Configuration Component Description 1 24VAC DC Input Output 2 Modbus to Gas Detectors 3 Modbus to BMS 4 Remote Silence Alarm Input 5 Forced Alarm Input 6 Aux Buz...

Page 9: ...ea where the MGS family gas detection instrument s is installed Failure to follow these warnings can result in serious bodily injury or death 3 2 Preliminary Inspection The MGS 401 Entrance Monitor ha...

Page 10: ...ductors used to supply mains meet all local electrical safety codes Failure to follow these warnings can result in serious bodily injury or death Locate the 24VAC DC power input terminal block Item 1...

Page 11: ...connected is a normally open connection The pushbutton in a remote location is used for personnel to silence the audible alarm momentarily with visual alarms still activated The audible alarm will ree...

Page 12: ...configure the BMS Modbus Server settings when use with higher level controls Please refer to Modbus best practice when making these choices It is important ALL of the following instrument settings co...

Page 13: ...ermination Please refer to Modbus best practice when making these choice The default is Not Enabled or OFF 2 Bank 2 Switches 2 and 3 are used to configure the number of sensors the MGS 401 is expectin...

Page 14: ...x Head screws in and X pattern from top left to lower right upper right to lower left and then the remaining center top and bottom screws Torque all screws to 15 to 20 lbf in 1 5 to 2 0 Nm 5 Power Up...

Page 15: ...m the MGS 401 Entrance Monitor will display that information on the LCD and respond with audible and visual alarms configured relay response and other countermeasures that are connected or configured...

Page 16: ...he Silence button on the MGS 401 front panel 3 consecutive times within 3 seconds The System screen will show some of the configuration of the MGS401 In addition it will display any MGS 401 Fault Code...

Page 17: ...MGS 401 User Manual 7 Modbus Map...

Page 18: ...MGS 401 User Manual...

Page 19: ...y in its original packing if possible as MSA Bacharach cannot be held responsible for any damage incurredduring shipping to our facility Location Contact Information Shipping Address United States Pho...

Reviews: