Troubleshooting
Alarm conditions on the electronic controller, Call BCS Tech Services at 937-665-0424
Unit will not reach temperature
Call your installation contractor to Determine proper refrigerant
charge. Dirty condenser?
Unit has shut off
Call BSC tech services or field Service; could be bad Compressor,
fans, controller or Pump
Alarm Signaling
Message
Cause
Outputs
“P1”
Thermostat probe failure
compressor and heating outputs off
(on dehumidification system only)
“P3”
Humidity probe failure
humidity regulation off
“HA”
High temp alarm
outputs unchanged
“LA”
Low temperature alarm
outputs unchanged
“HHA”
High humidity alarm
outputs unchanged
“HLA”
Low humidity alarm
outputs unchanged
In the instance of any of these alarms, call Bacchus Tech Services, or your local service contractor.
Dimensional /Electrical
BCS1000
BCS1000
BCS1500
BCS1500
BCS2000
BCS3000
Cond. Unit
Evap.
Con. Unit
Evaporator
Con. Unit
Con. Unit
Dims.
17”D x 13.3”W 18”D x 29.25”W
19”D x 16.2”W
18”D x 29.25”W
19”D x 21’W
25” D x 20”W
x 11.8”H
x 6.5”H
x 14”H
x 6.5”H
x 16.5”H
x 16”H
Weight
51 lbs.
49 lbs.
62 lbs.
51 lbs.
81 lbs.
135 lbs.
Refrigerant
3/8” suc.
3/8”sw
3/8” suc
3/8” sw x
3/8” suc
½” suc
Connection
1/4” dis.
¼” dis
½” sw
5/16” dis
3/8” dis
Water Supply
¼”
¼”
Connection
compression
compression
Condensate
¼ mpt
¼” mpt
Connection
Compressor
1/2 hp 115v
.65 hp 115v
1 hp 115v
1 ½ Hp
HP/voltage
208/230-1v
Electrical
compressor rla 10A
11A
8A
12.1A
compressor lra
53A
51A
43A
49A
cond. Unit MFS 20A
30A
15A
17.6A
cond. Unit mca 13.4A
13.4A
11.3A
12.1A
BTU capacity 40F 4857
6250
10200 (100 amb)
12,185
suc, 110 amb.