Cleaning
Replacing LED Lighting
Your Baby Lock will operate at best performance if it is kept clean at all times. The serger's cutting action
creates much more lint than you will find on conventional sewing machine.
Your serger's major moving parts are well protected and do not need to be oiled.
However, we recommend that you use the cleaning brush often during garment construction in order to keep
lint off the blades, the needle bar, the feed dog mechanism and loopers. If machine needs to be oiled, check
with your nearest Baby Lock retailer for use of high grade recommended sewing machine oil.
TO REMOVE NEEDLE PLATE PROCEED AS FOLLOW:
1. For safety reasons, unplug main power cord.
2. Raise and remove presser foot.
3. Select stitch length dial to rolled hem setting.
4. Remove needles from needle clamp.
5. Turn your handwheel until the upper looper is in the far right position.
6. To remove the needle plate, remove front screw with screwdriver and back screw with allen wrench
(fig. A).
7. With your right hand, first raise the needle plate in front of the blade. Pull slightly to the right, then remove
to the left.
8. Replace in reverse procedure.
9. Finally, position the needle plate so that the needles lower in the center of each hole on the needle plate
(fig.B). Then tighten both screws.
Your Baby Lock Enlighten is equipped with long-life LED lighting system, which is not necessary to change
bulbs.
In case of replacing LED unit, please contact your authorized Baby Lock dealer.