background image

 

 

APP

MODULE Documentation 

 

56  BAB TECHNOLOGIE GmbH 

 

 

 

Apps and app Instances:

 Backs up all app-related data. Individual apps and instances can be 

selected for backup from the drop-down menu. 

 

 

Figure 55: Selecting apps and app instances for backup 

 

 

 

Comments regarding the backup can be added in the “Comments” field. 

 

 

Click on “Create backup” to launch the backup process. 

 

 

The backup file is generated by the system and provided automatically for download using the 

browser download dialogue. 

 

 

 

Summary of Contents for 10491

Page 1: ...BAB TECHNOLOGIE GmbH APPMODULE Documentation Version 1 7 0 Type IP KNX EnOcean Item no 10491 10495 13501 Manual version IV As of 12 2021 Date 1 December 2021 EN...

Page 2: ...APPMODULE Documentation 2 BAB TECHNOLOGIE GmbH BAB TECHNOLOGIE GmbH H rder Burgstr 18 D 44139 Dortmund info bab tec de Tel 49 0 231 476 425 30 Fax 49 0 231 476 425 59 www bab tec de...

Page 3: ...e APPMODULE 20 Setting up the connection in EIBPORT 21 3 2 Using KNX net IP in the APPMODULE IP 23 4 APPMODULE KNX 24 4 1 APPMODULE KNX commissioning 24 4 1 1 KNX configuration 26 4 1 2 Address Settin...

Page 4: ...ral 50 8 3 Network 51 8 4 Module 52 8 5 EnOcean Editor 52 8 6 User administration 53 Disable Password Recovery 53 Smart Screens 53 8 7 Rem ote Servicing 54 8 8 Backup the settings 55 Creating a backup...

Page 5: ...ion Devices 31 Figure 27 EnOcean Configuration Monitor 32 Figure 28 EnOcean Settings 33 Figure 29 Calling up properties 34 Figure 30 EnOcean Device Configuration 34 Figure 31 Parameters 35 Figure 32 R...

Page 6: ...er that you can customise using the apps from the BAB APPMARKET This documentation will help to familiarise you with the product and facilitate implementation BAB TECHNOLOGIE GmbH Figure 1 APPMODULE K...

Page 7: ...available as IP for EIBPORT with KNX or with EnOcean interface 1 2 APPMODULE FUNCTIONAL PRINCIPLE On delivery the APPMODULE contains only the basic software and has no application installed You can p...

Page 8: ...objects unlimited Output objects 128 External antenna 2 50 m cable magnetic base and SMA connector Specific features A wide range of different smart home apps can be combined on one device SDK availab...

Page 9: ...the interests of technical progress The information in this documentation may therefore not necessarily be up to date Information on current APPMODULE firmware and on this description APPMODULE docum...

Page 10: ...power supply remove the screw plug in terminals see figure below Now connect the power supply cables to the respective screw plug in terminals see figure below Please consider the polarity Now you ca...

Page 11: ...n started the LED simulates a heartbeat The flashing interval increases depending on the device utilisation FLASHING RED Communication takes place via KNX Explanation The green Power Boot LED lights u...

Page 12: ...ion EnOcean Editor The language in the EnOcean Editor Java based application adjusts to the language set in the browser after start up from the browser If the app is used in BAB STARTER the language s...

Page 13: ...interface please proceed as described below Open a browser and enter the IP address of the APPMODULE into the address line Information about the factory settings can be found in chapter Initial Opera...

Page 14: ...igure 7 Back to the homepage ADJUSTING THE NETWORK SETTINGS OF YOUR COMPUTER In order to adjust the network settings of your computer and establish a connection to the device please proceed as describ...

Page 15: ...ODULE Documentation BAB TECHNOLOGIE GmbH 15 Then click Properties Figure 9 Ethernet status Select Internet protocol Version 4 TCP IPv4 and click Properties again Figure 10 Properties of the LAN connec...

Page 16: ...E Free IP address 192 168 1 228 Subnet mask 255 255 255 0 Now confirm your input with OK Close all windows until the Windows Network and Sharing Center Settings window is shown Thus you have adjusted...

Page 17: ...browser for factory settings 192 168 1 229 Figure 12 APPMODULE Webinterface The start page of the APPMODULE opens up Click Log In A login dialog appears For factory settings the login data is as follo...

Page 18: ...slated with www DeepL com Translator IP address subnet mask gateway Field for the static assignment of IP addresses Please make also sure that the subnet mask often 255 255 255 0 and the gateway entry...

Page 19: ...atically connects to the new IP address if possible Note Please bear in mind that you might have to reset the IP address of your computer to the initial value in order to be able to access the APPMODU...

Page 20: ...cility coupling needs to be set up Note For facility coupling between EIBPORT and the APPMODULE to work communication over UDP with port 1735 or another port if set is required Security installations...

Page 21: ...ation Advanced EIB yabus settings BMX UDP port Group address format Not relevant here Enter 3 Level xx y zzz This sets up communication from the APPMODULE to EIBPORT Communication from EIBPORT to the...

Page 22: ...ess of the APPMODULE to which you wish to connect here e g 192 168 1 224 Target system ID Please do not change this value The system ID must be 0 Rule 1 Enter the wildcard rule in both fields source t...

Page 23: ...NX must be provided by another device with a KNX interface e g a KNX IP Router and KNXnet IP Tunneling as an interface for ETS Proceed as follows to set up the KNXnet IP server Open the Configuration...

Page 24: ...o 10495 All KNX related settings are made over the Web interface of the APPMODULE Note For the ETS project please use a dummy application to record the use of the physical address of the APPMODULE Acc...

Page 25: ...st 2 physical addresses not used in the relevant line for KNXnet IP Tunneling Figure 21 KNX assigning a KNXnet IP tunneling address Note These addresses are required for establishing a connection for...

Page 26: ...eling Activates KNXnet IP Tunneling access to the device This connection can be used to program KNX devices or to exchange data The APPMODULE is the server The above address is used as the physical ad...

Page 27: ...s makes sense on the one hand if more KNX group addresses are required which can be sent on the KNX bus but at the same time not to do without the virtual group address range in order to keep the tele...

Page 28: ...hc en us articles 214496505 Licensing ETS Inside Now the ETS Inside Server is ready for use Further you have access to the KNX network via the ETS Inside Server with the ETS Inside Client installed t...

Page 29: ...868 3 Mhz Range 300 m in the free field 30 m in the building depending on the building material Input objects Any number Output objects 128 External antenna 2 50 m cable magnetic base and SMA plug con...

Page 30: ...e to be interpreted Thus it is important that sensor and actuator utilize the same EnOcean Profile EEP Device categories sensors EnOcean distinguishes between three device categories in its sensor tec...

Page 31: ...ess which only exists once This address allows the sending device to be identified Teaching Telegram LRN Telegram Is a special telegram used to teach the sensor to recognize the actuator that is to ad...

Page 32: ...nOcean Configuration Monitor Settings Settings You can configure the EnOcean module here EnOcean Devices Lists all EnOcean devices sorted by device id trans id EnOcean Monitor Lists all received EnOce...

Page 33: ...e you can switch the module on or off Repeater The repeater function is used to repeat a receiving signal in order to increase its range The following settings are available Check box activates Repeat...

Page 34: ...vices Show all devices Configured Devices Show only the devices which have already been configured New Unnamed Devices Show only the new and unnamed devices Advice If you are not sure which device has...

Page 35: ...oon as a profile is selected the corresponding KNX parameters are shown underneath 5 Select the corresponding profile of your EnOcean device If you are not sure about which profile your device speaks...

Page 36: ...ssignment in chapter KNX Addressing 9 When you have entered the addresses in the parameters as requested close the EnOcean Device Configuration window 10 Save the changes in the window EnOcean Configu...

Page 37: ...mine which device is emulated with which KNX telegram by the APPMODULE the device internally works with KNX group addresses also during the EnOcean execution Creating an emulated device Click on the b...

Page 38: ...ented ID Is the definite hardware address you have selected before Can not be modified at this point EnOcean Equipment Profil EEP Here the profile the emulated device should use is selected For more i...

Page 39: ...here is a 2 digit as well as a 3 digit representation 3 digit MG Main Group CG Central Group SG Subgroup MG CG SG 2 digit MG Main Group SG Subgroup MG SG Note The APPMODULE interface only supports the...

Page 40: ...e length of button presses for switch move step Separate Action You can assign further KNX addresses for the separate action both rockers at the same time Please note that this is only possible for bu...

Page 41: ...will be prompted to confirm that you really want to delete it Figure 34 Devices delete confirm Click on Delete to delete it Afterwards save the settings Only then will the device really be deleted If...

Page 42: ...ime when the currently imported project was last changed with the ETS The imported ETS project is then available in the App configuration USE ETS PROJECT After the installation of an app for the APPMO...

Page 43: ...main group to close it again Click with the left mouse button on a middle group All group addresses of this middle group are displayed Click again with the left mouse button on a middle group to clos...

Page 44: ...p address can be entered as a 2 digit or 3 digit group address The 2 digit group address is automatically converted into a 3 digit group address With the button Add the group address is added to the i...

Page 45: ...n the homepage of BAB APPMARKET https www bab appmarket de de or from the ToolTips of the corresponding application 1 Please call up the web interface of your APPMODULE 2 Click on the menu item App Ma...

Page 46: ...the app that you previously loaded from the APPMARKET and click OK See APPMODULE functional principle for information on purchasing apps Figure 42 Select APP 5 As soon as the next window opens the ins...

Page 47: ...lete instances Figure 45 Instance functions Colour Function Red Start instance Yellow Edit parameter Blue Display log Green Copy instance Orange Delete instance 7 1 1 NOTATION OF GROUP ADDRESSES The g...

Page 48: ...alization for example that an app update is present if a 0 is sent to the group address no update is present if a 1 is sent one or more updates are present Figure 46 Update Configuration If the Automa...

Page 49: ...Wait until the update is finished Figure 49 Update successful The update of the app does not overwrite existing group addresses Individual group addresses can be given If deleted if the function to w...

Page 50: ...ce name for your APPMODULE This name is then displayed in the Discovery Tool and BAB STARTER Location Edit the installation site so that the correct time zone can be set System time The current system...

Page 51: ...out Please note that an IP address may never be assigned twice DNS server DNS is the abbreviation for Domain Name System The DNS server converts Internet addresses for example www bab tec de into the...

Page 52: ...relevant for all APPMODULE versions IP 10491 KNX 10495 and EnOcean 13501 With IP 10491 and EnOcean 10495 the configuration regulates KNXnet IP communication For more information please see KNX configu...

Page 53: ...SSWORD RECOVERY If this option is selected the password cannot be reset and the device must be sent in if you lose the password Figure 52 User administration SMART SCREENS The displayed device names h...

Page 54: ...tivated again if the APPMODULE is restarted this is independent of the set time Remote Servicing Access can be deactivated at any time by clicking on Deactivate Remote Servicing Access Activate the Re...

Page 55: ...ware update Figure 54 Backup Restore CREATING A BACKUP Select the checkboxes under Modules to set which configuration data is to be backed up Configuration All configuration data except for app config...

Page 56: ...e selected for backup from the drop down menu Figure 55 Selecting apps and app instances for backup Comments regarding the backup can be added in the Comments field Click on Create backup to launch th...

Page 57: ...le in the selected backup file You can also use the checkboxes to select which modules are to be restored Configuration All configuration data except for the app configuration data Note The network se...

Page 58: ...mware update is free of charge The current firmware files can be found on the BAB homepage Proceed as follows to update the device Download the current firmware image from the download area www bab te...

Page 59: ...ion The device will be reset to factory defaults during the update Figure 58 Keep network settings Note If the Keep network settings checkbox is not selected the APPMODULE can be accessed at the defau...

Page 60: ...forms the heart of the HOOC VPN solution and offers a comprehensive user administration as well as many additional features such as a KNX bus monitor or alarm messages with push function Further inst...

Page 61: ...MODULE Documentation BAB TECHNOLOGIE GmbH 61 10 INFORMATION Important information on the APPMODULE can be found here Please have this information ready if support is required Figure 61 System Informat...

Page 62: ...olled IEEE Floating point number long EIS 9 DPT 14 yyy 4 Octet float value IEEE 754 32 Bit 4 byte float value Counter 16 Bit Unsigned EIS 10u DPT 7 yyy 0 65 535 16 Bit 2 byte unsigned value Counter 16...

Reviews: