3. Operation
3.1 Starting
Check if the Sieve ( no.07 Pic 2 ) is perfectly fit on the Central Shaft , the Central
Shaft Clogging Pin shall not clog the Shaft and the lid shall be secured by the two
handles ( Pic 11 ) .
Be sure the assembly procedure stated at item 2.2 has been correctly performed.
Only after this , the Centrifugal Juicer may be switched ON , by means of Switch
ON/OFF ( no. 13 Pic 1 ).
3.2 How to feed the Centrifugal Juicer
To use the Centrifugal Juicer Mod. CS/CSE , proceed as follows :
1.Withdraw the Stump ( no.01 Pic 1 ) from the Lid Feeding Throat ( no.02 Pic 1 ) .
2.Slice the products to be centrifuged to allow to introduce them into the Feeding
Throat .
3.Switch ON to start the Centrifuge Juicer
4.Place the product into the Feeding Throat ( no. 02 Pic 8 ) and using the Stump
slowly press them down .
5.After processing the first load , withdraw the Stump , and start it all again, as many
times needed .
6.Do be careful to avoid the juice to flow out of the Cup .
7.Sometimes with some product , and when a great quantity is being processed , the
Residual Exit might be obstructed . Such situation may be perceived when together
with the juice come out small fruit pieces , or when residuals stop to come out from
the Residual Exit (no. 15 Pic 7 ) .
8.If Residual Exit is obstructed, switch OFF the machine and unplug it , loose the two
Handles and lift the Lid .
9.Remove the residuals that might be obstructing the exit , wash the Lid with running
water , place back the Lid and tight it with the two Handles , then start operation again
.
10.When processing different kind of products , all the parts in contact with the prior
product shall be removed , cleaned and assembled back on their due places .
4
Problem Cause Solution
The machine does not Electric shortage. Check if the machine plug
Start. is into its socket , and if there is
electric energy on the network.
Problem with the Call Technical Assistance.
internal or external
machine electric
circuit .
The Lid is not duly Fit the Lid .
Fitted ( mod. CSE
Only )
The magnet support Call Technical Assistance.
Is out of its place
( Mod. CSE only ).
The Sieve does not come out. The Central Shaft , or Follow the item 3.3
the Sieve bore fitting procedures .
on the Shaft, are dirty
Small product pieces coming Lid residuals exit Follow item 3.2 ,
out with the juice , or no obstructed. procedures 8 and 9 .
residuals dropping off the
Residuals Exit .
Steel scratching steel noise The Feeding Throat is Call Technical Assistance
hitting on the knives to adjust the Feeding
of the Disc. Throat height.
Lid out of place Place the Lid correctly,
until the two Lid slits
touch the Handle beams
( no. 4 Pic 6 )
11