Cleaning System ud-800 Page 15
8.
Commissioning
Commissioning may be done only after reading and following the operating manual
carefully! Commissioning performed without following the operating manual and com-
plying with all applicable regulations can lead to damage to persons, property, or the
environment. Wear personal protective clothing. See section 2.2 ‐ Operational Safety).
After proper installation (Section 5 & 6) and mounting of the exhaust hose (Section 7.1), connection to
the compressed air supply (Section 7.2) and grounding (7.3), the machine can be commissioned.
8.1.
Containers for Cleaning Fluid
1 × 60 litre container filled with 30 litres (recirculating fluid) and 1 × 30 litre container filled with 30
litres (fresh fluid). See Figure 8-1. When refilling the fresh fluid, ensure that the container for circulating
liquid has a remaining capacity of 30 litres to prevent overflowing of liquid. It is recommended to also
renew the circulating liquid when refilling the clean rinse liquid.
8.2.
Positioning of Containers and Hose Allocation
1.
Remove the front cover and place the containers as shown in Figure 8-1.
2.
Moisten the draining and intake hoses incl. intake strainer with a wet cloth and insert the moist
hoses as follows: Insert the black draining hose (Ø 28 mm) and grey intake hoses into the 60
litre container, which is provided for recirculating cleaning fluid. Insert the transparent hose
into the 30 litre container for fresh cleaning fluid.
3.
Reinsert the front cover.
The machine is now ready for operation.
Figure 8-1
Recirculating fluid
(Black and grey hose)
Fresh fluid
(Transparent hose)