background image

7

2 Caution

a)  The AVANTI Fall Protection System (hereafter named as FPS) shall 

only be operated by users trained in daily inspection, use and work at 
heights.

b)   A user is trained on the correct usage of the AVANTI Fall Protection 

System (FPS) and is familiar with the following standards: EN 353-1, EN 
363 and EN 365.

c)   A certified technician has successfully participated in the AVANTI Fall 

Protection course.

d)   A certified technician is qualified personnel authorised by AVANTI to 

perform installation, inspection and maintenance tasks.

e)  The installation, maintenance and testing of the FPS may only be per-

formed by a certified technician.

f)  Users are obliged to read and understand this User’s Manual.
g)  A copy of the User’s Manual shall be handed out to the FPS users and 

shall be available for reference. 

h)  If more than one person is trusted with one of the above tasks, the 

employer shall appoint a supervisor in charge of operation. 

i)  If the FPS is re-sold outside the original country of destination, the 

reseller shall provide instructions for use, for maintenance, for periodic 
examination and for repair in the language of the country in which the 
product is to be used. 

j)  The ladder system shall be capable of supporting 15 kN. This shall be 

verified by calculations made by a qualified engineer or by static load 
testing. 

k)  The FPS shall not be used by persons under the influence of alcohol or 

drugs that may jeopardise the safety.

l)  The FPS shall not be used by persons affected by vertigo, heart or lung 

disorders, or other known weakening diseases/conditions.

m)  The FPS users shall be aware of the dangers of suspension trauma 

should a fall occur.

n)  Owner shall ensure that a rescue plan is in place and that the users are 

familiar with it. The rescue plan shall deal with any emergencies that 
could arise during ascent and descent with the FPS.

o)  No warranty is provided against damage resulting from reconstruction 

or modification of equipment or use of non-original parts which are not 
approved by the manufacturer. 

p)  The runner shall be handed out and treated as a personal protection 

equipment. 

q)  The weight of the user, excluding tools and equipment, shall not be less
 

than 40 kg. The weight of the user, including tools and equipment, shall

 

not exceed 136 kg. 

r)  The maximum number of multiple users in the ladder system is 3.  

The fall arrester must be attached to no more than one personal fall-
arrest system.

s)  In the first two meters above the ground level, the user may not be 

protected against hitting the ground if a fall occurs.. Other additional 
safeties shall be provided for this purpose.

t)  Prior to the first use of the FPS, a certified technician must inspect and 

approve the complete FPS.

u)  If oil, grease or the like has leaked onto the safety rail – wipe it off. 
v)  If oil, grease, chemicals or the like has leaked onto the shock absorber 

or in any kind been in contact with the webbing, have an AVANTI FPS 
certified technician replace the shock absorber. 

w)  The shock absorber has a limited life. Its date of expiration is printed 

on the shock absorber label. 

x)  The operation temperature of the FPS is -30º / +60º Celsius. 
y)  The FPS shall only be used in connection with a full body harness that 

is approved according to EN 361. 

z)  The FPS has been tested and approved according to EN 353-1:2014. 
aa)  The type-examination of the FPS has been performed by: FORCE 

Certification A/S, EC Notified Body 0200, Park Allé 345, DK-2605 
Brøndby. 

ab)  The production control of the FPS is performed by the same notified 

body.

ac)  These instructions shall be kept together with the permanent installed 

parts of the FPS (i.e. the rail system). 

 

 

Owner shall verify the need for FPS inspections with the  

 

local authority and comply with the standards specified. 

ad)  When working at heights, the user shall minimise both the risk of 

potential falls and the potential fall distance.

ae)  In order to avoid collisions with the ground or obstacles should a fall 

occur, the user shall verify the free space required beneath his/her 
actual position taking into account sharp edges, electrical conductivity 
and pendulum falls.

af)  The safety of the users depends upon the continued efficiency and 

durability of the FPS. Thus, regular periodic inspections shall be car-
ried out, minimum every 12 months.

ag)  All the FPS parts have been especially developed and tested for 

AVANTI´s FPS. Thus, they shall not be used as part of other Fall Pro-
tection Systems. 

MASTER 47840008 EN_CORREGIDO.indd   7

25/10/17   12:01

Summary of Contents for B-Speech Prim

Page 1: ...AVANTI FALL PROTECTION SYSTEM User s Installation and Maintenance Manual Runner 2000 2002 EagleDS Runner Original instructions MASTER 47840008 EN_CORREGIDO indd 1 25 10 17 12 01...

Page 2: ...l remedies Date of publication 11th Edition January 2017 Revision 3 10 10 2017 Manufacturer Avanti Wind Systems A S R nnevangs All 6 3400 Hiller d Denmark P 45 4824 9024 F 45 4824 9124 E info avanti o...

Page 3: ...er 2000 2002 from the safety rail 13 7 2 Instructions for use of EagleDS Runner 13 7 2 1 Attaching the EagleDS Runner to the safety rail 13 7 2 2 Releasing the EagleDS Runner from the safety rail 14 8...

Page 4: ...4 CE certificate of AVANTI Fall Protection System with Runner 2000 2002 MASTER 47840008 EN_CORREGIDO indd 4 25 10 17 12 01...

Page 5: ...5 CE certificate of AVANTI Fall Protection System with EagleDS Runner MASTER 47840008 EN_CORREGIDO indd 5 25 10 17 12 01...

Page 6: ...rict accordance with the return procedures of Avanti This warranty does not apply if the Product i has been altered without the authorization of Avanti or its authorized representa tive ii has not bee...

Page 7: ...excluding tools and equipment shall not be less than 40 kg The weight of the user including tools and equipment shall not exceed 136 kg r The maximum number of multiple users in the ladder system is 3...

Page 8: ...of two D rings marked A in the front of full body harness both rings act together like an only point of attachment do not individually 3 Description of equipment ah The combination of FPS parts in any...

Page 9: ...hall only be installed with original system parts b All FPS elements shall be checked on site even if the ladders are sup plied with the rails already fitted c The vibrations and torsional stress are...

Page 10: ...ladder This is also necessary even if the second or third last rung of the ladder are mounted with a rung fitting iii For each rail section mount a rung fitting at least every third rung never leaving...

Page 11: ...d the ladder bottom floor level shall not exceed 600 mm n During the erection phase of the wind turbine tower sections i e when the tower sections are being connected vertically a top rail stop shall...

Page 12: ...condition to be used again The Avanti fall arresters could be lubricated with a high perfor mance grease for instance HTS PTFE ABSOBON W rth for cold conditions Any grease to be used in Avanti fall ar...

Page 13: ...tioning at the ladder is required a separate dedicated and approved work positioning equipment shall be used 7 1 2 Releasing the Runner 2000 2002 from the safety rail a Before stepping in or stepping...

Page 14: ...il the push button pops out and you hear a click f Pull out the plunger and rotate the locking lever upwards see images below g Make sure that the runner is locked correctly by pulling the lever downw...

Page 15: ...echnician shall inspect the FPS both runner and rail Otherwise the warranty will be void and AVANTI will renounce all liability and claims that may appear The annual inspection may only be conducted b...

Page 16: ...em d During the erection of the wind turbine towers top and bottom rail stops shall be mounted on each individual tower section e Ensure that top and bottom rail stops are mounted 8 4 6 Fish joints a...

Page 17: ...MASTER 47840008 EN_CORREGIDO indd 23 25 10 17 12 02...

Page 18: ...Calle Los Angeles No 88 nave 1 50198 La Muela P 34 976 149524 F 34 976 149508 UK Avanti Wind Systems Limited Unit 2 Cunliffe Court Clayton Le Moors Accrington BB5 5JG P 44 0 1254 399923 USA Avanti Win...

Reviews: