background image

12

STOP

STOP

STOP

5  Inspection before the first use

7  Instructions for use 

6  Daily inspection 

The detailed installation procedure of the flange connection 
kit is available upon request to AVANTI. 

Before the first use, a certified technician shall inspect 
the FPS. 

The inspection before the first use shall be carried out following the 
inspection procedure. During the inspection, the “Annual Inspection 
Checklist” Appendix and the “Inspection log sheet” Appendix shall be 
filled in for future reference.

a)   Before using the runner, perform a daily inspection following the “Daily Inspec-

tion Checklist for Runner 2000/2002” Appendix or the “Daily Inspection 
Checklist for EagleDS Runner” Appendix. If any of the checks does not pass, 
the runner system cannot be used.

b)   During the ascent, look for visible damages or loose parts such as loose screws 

on ladder, rail or joints. 

c)   Equipment with defects or equipment that leaves doubt concerning safe use 

must be checked by a certified technician.  

 Do not use the FPS if it looks defective or if parts are missing.
If the FPS has blocked a fall or has been put out of service 
because of doubts, it may only be put back to service after an 
inspection by a certified technician is performed. The certified 
technician  shall confirm in writing that the FPS is found in safe 
condition to be used again. 

The Avanti fall arresters could be lubricated with a high perfor-
mance grease, for instance HTS+PTFE ABSOBON (Würth), for 
cold conditions. Any grease to be used in Avanti fall arresters 
must be verified and approved by Avanti. 

7.1 Instructions for use of Runner 2000/2002 

    7.1.1 Attaching the Runner 2000/2002 to the safety rail 
      
     

Before using the runner, make sure that you are wearing an

  approved full body harness, and that it is properly adjusted to a  
  snug fit (it should not be used if loose). Before attaching the  
  runner to the rail, ensure that you are in a safe area (ground level) 
  or attached to an alternative fall protection.

Before attaching the runner to the rail, ensure that it is attached to the 
D-ring marked “A” of the full body harness in order to avoid dropping it. 
The carabiner shall only be connected to the D-ring marked “A” of 
the full body harness located on the front side of the user and located 
at the chest height.
The D-ring marked “A” shall comply with the demands for climbing in 
vertical fall arrest safety systems on ladders (see the user´s manual of 
the full body harness).
When attaching the carabiner, ensure that the shock absorber is 
not twisted between the runner and the carabiner. A twisted shock 
absorber may cause the FPS to fail. 

a)  Place the runner on the  

safety rail ensuring that the  
arrow on the plate of the  
runner points upwards.  
Otherwise, the runner will  
not arrest a fall.

Flange connection kit

MASTER 47840008 EN_CORREGIDO.indd   12

25/10/17   12:01

Summary of Contents for B-Speech Prim

Page 1: ...AVANTI FALL PROTECTION SYSTEM User s Installation and Maintenance Manual Runner 2000 2002 EagleDS Runner Original instructions MASTER 47840008 EN_CORREGIDO indd 1 25 10 17 12 01...

Page 2: ...l remedies Date of publication 11th Edition January 2017 Revision 3 10 10 2017 Manufacturer Avanti Wind Systems A S R nnevangs All 6 3400 Hiller d Denmark P 45 4824 9024 F 45 4824 9124 E info avanti o...

Page 3: ...er 2000 2002 from the safety rail 13 7 2 Instructions for use of EagleDS Runner 13 7 2 1 Attaching the EagleDS Runner to the safety rail 13 7 2 2 Releasing the EagleDS Runner from the safety rail 14 8...

Page 4: ...4 CE certificate of AVANTI Fall Protection System with Runner 2000 2002 MASTER 47840008 EN_CORREGIDO indd 4 25 10 17 12 01...

Page 5: ...5 CE certificate of AVANTI Fall Protection System with EagleDS Runner MASTER 47840008 EN_CORREGIDO indd 5 25 10 17 12 01...

Page 6: ...rict accordance with the return procedures of Avanti This warranty does not apply if the Product i has been altered without the authorization of Avanti or its authorized representa tive ii has not bee...

Page 7: ...excluding tools and equipment shall not be less than 40 kg The weight of the user including tools and equipment shall not exceed 136 kg r The maximum number of multiple users in the ladder system is 3...

Page 8: ...of two D rings marked A in the front of full body harness both rings act together like an only point of attachment do not individually 3 Description of equipment ah The combination of FPS parts in any...

Page 9: ...hall only be installed with original system parts b All FPS elements shall be checked on site even if the ladders are sup plied with the rails already fitted c The vibrations and torsional stress are...

Page 10: ...ladder This is also necessary even if the second or third last rung of the ladder are mounted with a rung fitting iii For each rail section mount a rung fitting at least every third rung never leaving...

Page 11: ...d the ladder bottom floor level shall not exceed 600 mm n During the erection phase of the wind turbine tower sections i e when the tower sections are being connected vertically a top rail stop shall...

Page 12: ...condition to be used again The Avanti fall arresters could be lubricated with a high perfor mance grease for instance HTS PTFE ABSOBON W rth for cold conditions Any grease to be used in Avanti fall ar...

Page 13: ...tioning at the ladder is required a separate dedicated and approved work positioning equipment shall be used 7 1 2 Releasing the Runner 2000 2002 from the safety rail a Before stepping in or stepping...

Page 14: ...il the push button pops out and you hear a click f Pull out the plunger and rotate the locking lever upwards see images below g Make sure that the runner is locked correctly by pulling the lever downw...

Page 15: ...echnician shall inspect the FPS both runner and rail Otherwise the warranty will be void and AVANTI will renounce all liability and claims that may appear The annual inspection may only be conducted b...

Page 16: ...em d During the erection of the wind turbine towers top and bottom rail stops shall be mounted on each individual tower section e Ensure that top and bottom rail stops are mounted 8 4 6 Fish joints a...

Page 17: ...MASTER 47840008 EN_CORREGIDO indd 23 25 10 17 12 02...

Page 18: ...Calle Los Angeles No 88 nave 1 50198 La Muela P 34 976 149524 F 34 976 149508 UK Avanti Wind Systems Limited Unit 2 Cunliffe Court Clayton Le Moors Accrington BB5 5JG P 44 0 1254 399923 USA Avanti Win...

Reviews: