IMPORTANT WARNINGS 

 

 

THIS  APPLIANCE  SHALL  ONLY  BE  INSTALLED/SERVICED  BY 
AN AUTHORISED INSTALLER. 

THIS  APPLIANCE  MUST  BE  INSTALLED  IN  ACCORDANCE 
WITH THE SPECIFIED INSTRUCTIONS AND SPECIFICATIONS. 

IMPROPER 

INSTALLATION 

OR 

OPERATION 

OF 

THIS 

APPLIANCE MAY RESULT IN PRODUCT FAILURE WHICH MAY 
LEAD  TO  PROPERTY  DAMAGE,  PERSONAL  INJURY  OR 
DEATH. 

CAUTION  MUST  BE  TAKEN  WHEN  OPERATING  THIS 
APPLIANCE  TO  MINIMISE  RISK  OF  FIRE.  THE  APPLIANCE 
MUST NOT BE LEFTON UNATTENDED. 

REGULAR  INSPECTIONS  BY  AN  AUTHORISED  SERVICE  PERSON  ARE  STRONGLY  RECOMMENDED 
TO ENSURE PROPER AND SAFE FUNCTIONING OF THIS APPLIANCE. 

AFTER  ANY  SERVICING  OR  ADJUSTING  OF  GAS  CONNECTED  COMPONENTRY,  GAS  LEAK  TEST 
MUST BE CARRIED OUT TO ENSURE THERE ARE NO GAS LEAKING HAZARDS. 

NEVER  STORE  ANY  FLAMEABLE  LIQUIDS/VAPOURS  IN  VACINITY  OF  THIS  APPLIANCE.  NEVER 
SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION. 

ENSURE  ANY  TRANSIENT  PROTECTION  IS  REMOVED  BEFORE  INSTALLING  THE  APPLIANCE 
ENSURING ANY POSSIBLE DAMAGE TO THE APPLIANCE OR COMPONENTS/ PARTS THAT MAY HAVE 
BEEN SUSTAINED DURING TRANSPORTATION IS REPORTED TO THE MANUFACTURER. 

THIS APPLIANCE IS NOT INTENDED TO BE USED IN A MARINE ENVIRONMENT. ENSURE APPLIANCE 
IS INSTALLED IN A STABLE POSITION. 

FAILURE TO FOLLOW THE INFORMATION PROVIDED IN THIS BOOKLET WILL VOID THE B&S 

WARRANTY AND MAY RESULT IN DAMAGE TO EQUIPMENT OR INJURY TO PERSONNEL. 

 
Installation Instructions 
 

Regulations 

The appliance 

must

 

be installed only by authorised persons and in accordance with the manufacturer’s 

installation instructions, local gas fitting regulations, municipal building codes, AS 5601 

– Gas Installations 

and any other health and safety regulations, local authority, gas, electrical any other statutory regulations. 

 

Data Label 

The data label is located on the front of the appliance.  This appliance is suitable for Natural Gas and LPG.  
Please ensure that the gas supply matches the Data Label ensuring that the gas supply is correct for the 
appliance being installed and that adequate supply pressure and volume is available 

– refer to appliance 

data plate for Mj/hr consumption, injector sizes of main burners/pilots, etc. 

 

Ventilation 

It is strongly recommended that the appliance is installed under an extraction hood.  Ventilation must be in 
accordance with AS5601 - Gas Installations.  In general, the appliance should have adequate ventilation for 
complete combustion of gas, proper flueing and to maintain temperature of immediate surroundings within 
safe limits.  It is 

strongly

 recommended that this appliance is installed under an extraction hood. 

 

Summary of Contents for CSP Series

Page 1: ...www bscommercialkitchens com Please ensure this booklet is kept in a safe and prominent location for future reference The reproduction on or copying of any part of this booklet via any means is strictly forbidden unless agreed to in writing by the manufacturer Owing to continual product development and improvements to its products B S Commercial Kitchens Pty Ltd reserves the right to change the pr...

Page 2: ...as Connection 5 Pressure Test Point 5 Before Leaving Commissioning 5 Operating Instructions 6 IMPORTANT WARNING 6 Figure 1 CSP Series Stock Pot Knowing Your Appliance 6 IMPORTANT WARNING 7 Lighting Instructions 7 Shutdown Procedure 7 Maintenance and Care 7 Servicing Instructions 8 Gaining Access to Gas and or Water System 8 Pilot and Flame Safeguard 8 Servicing of Main Gas Valve Flame Failure Safe...

Page 3: ...your new B S appliance there are two important things you can do 1 Ensure you read this booklet carefully and carefully follow the instructions given Ensure that this booklet is kept in a safe and prominent location for future reference 2 Should you be unsure of any aspect of the operation performance servicing and installation of the appliance please contact your B S dealer immediately In most in...

Page 4: ...ENSURE APPLIANCE IS INSTALLED IN A STABLE POSITION FAILURE TO FOLLOW THE INFORMATION PROVIDED IN THIS BOOKLET WILL VOID THE B S WARRANTY AND MAY RESULT IN DAMAGE TO EQUIPMENT OR INJURY TO PERSONNEL Installation Instructions Regulations The appliance must be installed only by authorised persons and in accordance with the manufacturer s installation instructions local gas fitting regulations municip...

Page 5: ...Natural gas or 2 60 kPa LPG with the burners operating at maximum Before Leaving Commissioning Check all connections for gas leaks with soap and water Do not use a naked flame for detecting leaks Ignite the pilot and main burners as prescribed below to ensure correct operation of gas valves burners and ignition When satisfied with the operation of the appliance please instruct the user on the corr...

Page 6: ...e vicinity of this appliance while it is in operation DO NOT store or use flammable liquids or items in the vicinity of this appliance Prior to lighting smell area surrounding the appliance for gas please note that as some gas types are heavier than air we recommended the operator to also smell the floor around the appliance In the event you smell gas DO NOT light any appliance DO NOT touch operat...

Page 7: ...n main burner control clock wise to the OFF position B Observe main burner is extinguished C Turn pilot light control clock wise to the OFF position D Observe pilot light is extinguished Maintenance and Care To ensure longevity and continued performance efficiency of you appliance a good cleaning and maintenance program is paramount In general the use of steel wool abrasive cloths cleaners powders...

Page 8: ...ase ensure the gas supply is turned off isolated FAILURE TO DO SO WILL VOID B S WARRANTY AND MAY RESULT IN DAMAGE TO EQUIPMENT OR INJURY TO PERSONNEL Gaining Access to Gas and or Water System To gain access to gas system components 1 Gently remove pilot control knob by pulling backwards 2 Undo screw located at the centre of the main gas handle and gently remove handle 3 Undo front panel screws loc...

Page 9: ...n located after galvanized elbow located after main gas control ball valve 2 Remove pilot assembly from front left burner lug by undoing wing nut located underneath 3 Undo wing nuts located on either side of the burner which hold the burner onto the main burner bar 4 Gently lift burner from rear and pull towards the rear of the appliance 5 REASSEMBLE IN REVERSE ORDER Adjustments Pilot 1 Remove fro...

Page 10: ... control valve Check connection of the thermocouple to the control is not loose Adjust positioning of thermocouple to ensure pilot flame is hitting thermocouple Contact manufacturer or authorised service agent Contact manufacturer or authorised service agent Pilot established main burner not lighting Faulty thermocouple Faulty flame failure control valve Contact manufacturer Contact manufacturer T...