background image

10 

 

Table 3: Troubleshooting 

FAULT 

POSSIBLE CAUSE 

CHECKS 

Pilot light not igniting 

Blockage of pilot 

 
 
 
 

Adjustment of pressure from flame 

control 

Check pilot injector is not blocked 

as described in servicing 

instructions - pilot and flame 

safeguard 

 

Check gas pressure to pilot as 

described under servicing 

instruction - adjustments 

Pilot light not establishing 

 
 
 

Positioning of thermocouple 

 
 
 
 

Faulty thermocouple 

 
 

Faulty flame failure control valve 

Check connection of the 

thermocouple to the control is not 

loose 

 

Adjust positioning of thermocouple 

to ensure pilot flame is hitting 

thermocouple 

 

Contact manufacturer or 

authorised service agent 

 

Contact manufacturer or 

authorised service agent 

Pilot established, main burner not 

lighting 

Faulty thermocouple 

 

Faulty flame failure control valve 

Contact manufacturer 

 

Contact manufacturer 

 
 

To obtain further service information concerning this appliance, pleased contact; 

B&S Commercial Kitchens Pty Ltd

 

57 Plateau Road 
Reservoir   VIC   3073 
Tel.: + 61 3 9469 4754 

Fax.: + 61 3 9469 4504 

E-mail: 

[email protected]

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Summary of Contents for CSP Series

Page 1: ...www bscommercialkitchens com Please ensure this booklet is kept in a safe and prominent location for future reference The reproduction on or copying of any part of this booklet via any means is strictly forbidden unless agreed to in writing by the manufacturer Owing to continual product development and improvements to its products B S Commercial Kitchens Pty Ltd reserves the right to change the pr...

Page 2: ...as Connection 5 Pressure Test Point 5 Before Leaving Commissioning 5 Operating Instructions 6 IMPORTANT WARNING 6 Figure 1 CSP Series Stock Pot Knowing Your Appliance 6 IMPORTANT WARNING 7 Lighting Instructions 7 Shutdown Procedure 7 Maintenance and Care 7 Servicing Instructions 8 Gaining Access to Gas and or Water System 8 Pilot and Flame Safeguard 8 Servicing of Main Gas Valve Flame Failure Safe...

Page 3: ...your new B S appliance there are two important things you can do 1 Ensure you read this booklet carefully and carefully follow the instructions given Ensure that this booklet is kept in a safe and prominent location for future reference 2 Should you be unsure of any aspect of the operation performance servicing and installation of the appliance please contact your B S dealer immediately In most in...

Page 4: ...ENSURE APPLIANCE IS INSTALLED IN A STABLE POSITION FAILURE TO FOLLOW THE INFORMATION PROVIDED IN THIS BOOKLET WILL VOID THE B S WARRANTY AND MAY RESULT IN DAMAGE TO EQUIPMENT OR INJURY TO PERSONNEL Installation Instructions Regulations The appliance must be installed only by authorised persons and in accordance with the manufacturer s installation instructions local gas fitting regulations municip...

Page 5: ...Natural gas or 2 60 kPa LPG with the burners operating at maximum Before Leaving Commissioning Check all connections for gas leaks with soap and water Do not use a naked flame for detecting leaks Ignite the pilot and main burners as prescribed below to ensure correct operation of gas valves burners and ignition When satisfied with the operation of the appliance please instruct the user on the corr...

Page 6: ...e vicinity of this appliance while it is in operation DO NOT store or use flammable liquids or items in the vicinity of this appliance Prior to lighting smell area surrounding the appliance for gas please note that as some gas types are heavier than air we recommended the operator to also smell the floor around the appliance In the event you smell gas DO NOT light any appliance DO NOT touch operat...

Page 7: ...n main burner control clock wise to the OFF position B Observe main burner is extinguished C Turn pilot light control clock wise to the OFF position D Observe pilot light is extinguished Maintenance and Care To ensure longevity and continued performance efficiency of you appliance a good cleaning and maintenance program is paramount In general the use of steel wool abrasive cloths cleaners powders...

Page 8: ...ase ensure the gas supply is turned off isolated FAILURE TO DO SO WILL VOID B S WARRANTY AND MAY RESULT IN DAMAGE TO EQUIPMENT OR INJURY TO PERSONNEL Gaining Access to Gas and or Water System To gain access to gas system components 1 Gently remove pilot control knob by pulling backwards 2 Undo screw located at the centre of the main gas handle and gently remove handle 3 Undo front panel screws loc...

Page 9: ...n located after galvanized elbow located after main gas control ball valve 2 Remove pilot assembly from front left burner lug by undoing wing nut located underneath 3 Undo wing nuts located on either side of the burner which hold the burner onto the main burner bar 4 Gently lift burner from rear and pull towards the rear of the appliance 5 REASSEMBLE IN REVERSE ORDER Adjustments Pilot 1 Remove fro...

Page 10: ... control valve Check connection of the thermocouple to the control is not loose Adjust positioning of thermocouple to ensure pilot flame is hitting thermocouple Contact manufacturer or authorised service agent Contact manufacturer or authorised service agent Pilot established main burner not lighting Faulty thermocouple Faulty flame failure control valve Contact manufacturer Contact manufacturer T...

Reviews: