Technical characteristics of the handset
• Working temperature range: from 0 °C
to +35 °C.
• Dimensions: 83,3x211x48 mm.
ENTRY PANEL AEPW2
The entry panel is a wall unit with a sin-
gle button capable of calling two resi-
dences.
A green LED illuminates the button and
a sound confirms a call has been made.
There are two potentiometers (fig. 4):
P1
(
), to regulate the microphone le-
vel,
P2
(
), to regulate the speaker level.
It is possible to connect a lock to the sy-
stem which may be 12Vac or 12 Vdc
max 0.5A.
It is always advisable to mount the pa-
nel in a sheltered position.
Function of terminals (fig. 4)
L+
positive data extension
+
power supply 12÷18 V
L–/–
data extension in common/
power supply
–
connection
solenoid lock
Function of JP4 jumper (fig. 4) (Tab. 2)
(call button selector)
Default (on) Selects single call activation.
Remove
JP4
to activate second call.
Technical characteristics of the entry
panel
• Working temperature range: from 15
°C to +50 °C.
• Dimensions: 95x170x28,5 mm.
APSW2 POWER SUPPLY
The power supply is a 9VA transformer
electronically and temperature protec-
ted against overloads and short cir-
cuits.
It is supplied with a diodes' bridge that
supplies a stabilised continuous tension
of 18 V.
A single power supplier is provided for
systems connected to the te e –
of the plate and the intercom.
Function of terminals (fig. 5)
230V
main entrance
+
18V
stabilized continuous
–
current flow
Technical characteristics of the power
supply
• Working temperature range: from 0 °C
to +35 °C.
• Dimension: low-profile 3-unit model,
for installation on DIN rail (fig. 6).
NOTE. Electronic protection of transfor-
mer and power supplier against overlo-
ads and short-circuits is provided rather
than protection through fuses: to reset
normal operating mode in case of inter-
ruption the following instructions must
be followed:
a) remove power supply;
b) eliminate cause of arrest;
c) give power supplier time to cool for at
least one minute;
d) reconnect device.
TECHNICAL CHARACTERISTICS
OF THE KIT
• Power Supply: 230 V +6% -10%,
50/60 Hz.
Protection through self-resetting ther-
mal device.
• It is possible to connect electric lock
releases, impulse or continuous acti-
vation, (12Vac or cc 0,5 A).
WARNING
The system operates at a very low sa-
fety voltage (15÷18 Vdc): it must not
be connected to a higher voltage.
ASSEMBLY
INSTRUCTIONS
ARW2 Handset
Fix the back plate directly to the wall (fig
7) or to the recessed mounting box (fig
8 o fig. 9) using the fixings provided.
For a surface mount cable follow the in-
structions in figure 10.
Avoid excessive tightening of screws on
walls that are not perfectly flat.
Connect the cable as per fig 2 and se-
cure the front of the handset as indica-
ted in fig 11.
AEPW2 Entry Panel
Follow the instructions in fig 12 to remo-
ve the front plate.
Remove the cable grip (fig 13).
WARNING. Were cables come through
the wall they must enter the unit through
the cable entry point as per fig 14.
Fix the back plate directly to the wall (fig
15) using the fixings provided.
Connect and replace the cable grip.
Ensure the front panel is correctly loca-
ted as per fig 16 and then secure it.
APSW2 Power supplier
The unit can be installed in boxes with
DIN rail (EN 50022).
For overall dimensions see fig. 6.
The unit can also be installed against
the wall using the two provided plastic
tabs (fig. 17).
WARNING
Do not open or tamper with the unit;
high voltage on the inside.
USER INSTRUCTIONS
WARNING
In case of damage, modifications or
interventions on system devices (po-
wer supplier, etc.) request help from
specialized professionals.
ARW2 Handset
The unit has two buttons for the follo-
wing controls (fig. 1):
Door lock release (
1
)
•
Intercom operating mode (
2
)
(
1
) The door lock release control can al-
so be activated without lifting the recei-
ver.
(
2
) The auxiliary control can be used to
activate auxiliaries such as stairs li-
ghting, low voltage supplementary and
relay lock release.
A call from the external unit is characte-
rized by a dual tone sound.
Intercommunicating operating mode
To call units calling on the same inter-
com group, lift the receiver, push the
button • (the call signal is a note with a
continuous tone) and wait for the con-
nection.
Internal conversation cannot be heard
on the outside.
If a user makes a call to a busy unit an
engaged signal is given.
AEPW2 Entry panel
In order to write your name on the label,
extract the label cover first, then the la-
bel (fig. 18).
DISPOSAL
Do not litter the environment with pac-
king material: make sure it is disposed
of according to the regulations in force
in the country where the product is
used.
When the equipment reaches the end of
its life cycle, take measures to ensure it
is not discarded in the environment.
The equipment must be disposed of in
compliance with the regulations in for-
ce, recycling its component parts whe-
rever possible.
Components that qualify as recyclable
waste feature the relevant symbol and
the material’s abbreviation.