Troubleshooting
Cause
Measure
Mains plug is disconnected or not
plugged in properly.
Plug the mains plug into the socket outlet and
ensure it fits properly.
Mains cable is damaged; e.g. a wire is
broken (can also occur without external
damage).
Have a centre authorised to carry out repairs
replace the mains cable.
ª
Customer-supplied fuse (building fuse) is
defective.
Check customer-supplied fuse and replace it if
necessary.
Unit electrical system is defective.
Notify a centre authorised to carry out repairs.
ª
Cause
Measure
The fan cable plug is unplugged or not
plugged in properly.
Plug in the fan cable mains plugs into the unit
socket outlets on the odour filter box.
ª
Temperature sensors have been trigge-
red.
Reset the temperature monitoring display.
ª
Section "Restarting the unit after the tempera-
ture sensors are triggered"
Unit electrical system is defective.
Notify a centre authorised to carry out repairs.
ª
Cause
Measure
Unit is exposed to draughts.
Stop the draughts.
– or –
Change location of unit.
Power step of extraction set too low.
Select higher power step.
ª
Section "Selecting extraction power step"
Filter cassettes saturated.
Clean filter cassettes.
ª
Section "Cleaning lid, filter cassettes, extraction
bridge frame and exhaust ducts"
The fan cable plug is unplugged or not
plugged in properly.
Plug in the fan cable mains plugs into the unit
socket outlets on the odour filter box.
ª
Air baffle is missing or is not inserted
properly.
Check air baffle and insert properly if neces-
sary.
ª
Section "Installing the splash guard and air
baffle"
Seal on odour filter box damaged or is
missing.
Check seal and have replaced.
ª
Section "Checking cover seals on the odour
filter box"
All electrical components
(fans, LED lighting,
socket outlets) are
not connected to the
electricity supply
Fan is not working
Extraction performance
inadequate