background image

 

MB-PULSE4_QUG v1.0 

Quick User Guide 

v1.0 

MB-PULSE4

 

 

 

 

                                                         

   

 

Pulse to wired MBUS converter module 

 

Product description 

 

 

 

 

The MB-PULSE4 module is a device that allows to convert the incoming pulses into a 
Wired MBUS signal. It is equipped with four inputs, so it is possible to simultaneously 
connect up to four pulse emitter devices. The device must be configured by using the 
BMBUS configuration software. This allows to set  primary address, medium options, 
measurement units, pulse value and it allows to read and manage the MBUS network, 
when properly connected to a compatible level converter. To download the software, 
please connect to the following lin

http://www.bmeters.com/en/bm_product/m-bus-

master/

 and  press  the button “software”. Please  refer to the configuration  software 

manual for a detailed description of the configuration features and options available. 
The module can be connected to any meter equipped with pulse output, regardless the 
brand, size and version.  

 

Package Content 

 

MB-PULSE4 module 

 

Anti-tampering seal 

 

Installation guide 

 

Technical data 

 

Working temperature: From +1°C to +55 °C 

 

Power supply voltage: MBUS n Lithium battery  3V  Li-SOCI

2

 (backup)* 

 

Maximum battery duration: 1 year** 

 

MBUS consumption: 1 unit load (≤1,5 mA) 

 

Transmission protocol: MBUS EN14757-3  

 

Configuration: by using BMBUS software*** 

 

Protection level: IP65 

 

Measurement units available: L- Wh – Kj – N/A 

 

Mediums available: Electricity, water, hot/cold water, heat cost allocator (HCA), 
heat meter, cooling meter, gas, oil, pressure, other 

 

Dimensions: 70mm x 139mm H=35mm  

 

Weight: 100g 

 
* Battery is replaceable, spare batteries are supplied by B METERS, DO NOT REPLEACE the battery with 
wrong types. Disconnecting the battery from the board and the module from the network in the same 
time will cause the configuration lost, it will be necessary to reconfigure the device. 
** In the event that the module remains permanently disconnected from the MBUS network 
*** even during the configuration it is necessary that the device stays  connected to a MBUS network 
and to a MBUS master 
 

Installation 

The  module  should  be  mounted  on  the  wall,  by  using  two  screws  on  the  two  holes 
pointed out by the arrows in the picture below.  
To  open  the  device,  remove  the  four  screws  on  the  edges  of  the  cover  and  lift  it 
carefully. 

 

 

 

 

 

Connections

 

Plug the cables of pulse output devices and MBUS network passing through the rubber 
cable-glands available, marked as Input 1-2 and Input 3-4 in the picture above. 
Input 1-2: Connect the wires of the first pulse output to the A and B terminals, as shown 
in the picture. Connect the wires of the second pulse output to the C and D terminals, 
as shown in the picture. 
Input 3-4: Connect the wires of the third pulse output to the E and F terminals, as shown 
in the picture. Connect the wires of the fourth pulse output to the G and H terminals, 
as shown in the picture. 
MBUS: connect the device to the MBUS network by using the X and Y terminals. 
 

Contacts type 

Counting contacts: A [+] / B [-] for meter n.1, C [+] / D [-] for meter n.2, E [+] / F [-] for 
meter n.3, G [+] / H [-] for meter n.4. 
It is possible to connect pulse output devices both REED and Open Collector type. In 
this second case, it is necessary to respect the polarity.  
 

Configuration 

Configure the module by using the BMBUS software. 
The device will then answer via MBUS with four different secondary addresses, one per 
each input. The default addresses are the following: 

 

Input 1: Serial  01 (e.g.: 12345601); 

 

Input 2: Serial  02 (e.g.: 12345602); 

 

Input 3: Serial  03 (e.g.: 12345603); 

 

Input 4: Serial  04 (e.g.: 12345604); 

 
When the configuration is completed, close the box with the screws. 
To avoid any potential tampering of the module, you can place the anti-tampering seal 
(supplied together with the module) between the base of the box and the cover. 

 

Safety

 

 

During the installation process, handle the device with care, don’t crush, don’t bent, 
don’t  exposure  to  electrostatic  discharges  which  could  damage  permanently  the 
device, do not install close to heat sources (radiators, conditioners, convectors etc..).

 

 

The MB-PULSE4 module doesn’t contain hazardous materials in accordance with 
European  directives 91/157/EEC, 93/86/EEC, and  2002/95/EC(RoHS). The  device 
requires  specific  disposal  on  the  end  of  its  lifetime.  Recycling  is  mandatory  or 
recommended  following  the  Directive  RAEE  2012/19/UE  inside  European  Union 
region, or anyway dispose in accordance with local laws and regulations. Do not 
burn, or undergo to high temperatures. 

 

 

The  MB-PULSE4  works  reliably  in  the  environmental  conditions  specified  in  this 
manual.  Any  unauthorized  intervention  and/or  modification  may  cause 
malfunctions or total damaging of the product. 

 

Warranty 

The warranty period is set at 24 (twenty-four) months from the date of the shipping of 
the  material.  Warranty  is  against  defects  in  materials  or  workmanship  when  the 
product is properly used and maintained in normal efficiency. This Warranty is valid and 
enforceable  in  the  country  where  the  product  was  purchased.  In  the  event  that  the 
product has been purchased in a country of the European Union, the warranty is still 
valid in all countries of the Community. 
 
To obtain warranty service, it is requested to comply with the following clauses:  
1.

 

Products must be delivered for repair at the expense of the customer.  

2.

 

The product warranty will be subject to the exhibition of a tax document (receipt, 
receipt or bill of sale), which attests to the date of purchase of the product.  

3.

 

The repair will not affect the original date of expiration of the warranty and will 
not involve the renewal or extension thereof.  

4.

 

If at the time of the repair, the product has not any defect, it will be charged the 
costs of the technical analysis. 

5.

 

The warranty is void if the failure was due to: impacts, falls, misuse or abuse of 
the  product,  use  of  non-original  batteries,  accidents,  product  alteration, 
replacement/detachment  of  seals  and/or  product  tampering.  The  same  also 
does not cover damage caused during transport if packages used are unsuitable.  

6.

 

The warranty is not covering the battery of the product. 

7.

 

The  warranty  does  not  cover  the  inability  to  use  the  product,  other  costs 
incidental  or  consequential  damages  or  other  expenses  incurred  by  the 
purchaser. 

8.

 

The warranty doesn’t cover damage to the product caused by usage in any other 
way than described in this manual. 

 
 

Support on the products 

If  the  product  needs  to  be  sent  to  the  technical  assistance,  contact  your  dealer  or 
contact the BMETERS After sales service a

[email protected]

 

 

Declaration of Conformity 

Hereby, B METERS, declares that this  MB-PULSE4  is in compliance with the essential 
requirements and other relevant provisions of Directive 2004/108/EC. 
The  complete  declaration  can  be  downloaded  from  the  official  website 

www.bmeters.com

 

Contact Info 

 

B METERS Srl 

 

Via Friuli 3 
Gonars (UD) – 33050  
Italy 

Tel: +39 0432931415 
Fax: +39 0432992661 
E-Mail (sales/informations)

[email protected]

  