background image

ALARMS

The IWM-TX5 module has several built-in alarm functions:

Alarm

Description

Activation

Troubleshooting

Reset

Radio telegram

Reverse flow alarm

Reverse flow detected, a flow in the 

opposite direction was detected

The error is triggered after a continuous 

reverse flow greater than the set value.

Settable values (liters): 20/50/200

Check the water supply and 

meter installation

Reset the alarm via NFC

The payload contains the alarm status and 

the total of reverse flow. After the reset, the 

status is updated

Qmax overflow alarm

Water meters were used in 

improper conditions, the flow rate 

exceeded the operating conditions. 

The manufacturer’s warranty is 

invalidated

The error is triggered after the meter 

operates at a flow rate above Q4 for 10 

consecutive minutes.

Settable values (m3 / h): 1.25 / 1.5 / 2/3 / 

3.125 / 5

Check the water supply

Reset the alarm via NFC

The payload contains the alarm status. After 

the reset, the status is updated

NFC fraud alarm

The presence of an NFC field has 

been detected

The presence of an NFC field is checked at 

regular intervals to prevent fraud

Check for extraneous NFC fields

Reset the alarm via NFC

The payload contains the alarm status and 

the alarm activation date. After the reset, the 

status is updated

Low battery alarm

A battery voltage of less than 2.65V 

has been detected

It is activated when the battery voltage 

drops below the 2.65V threshold

Permanent error

Permanent error

The payload contains the alarm status and 

activation date

Leakage alarm

Continuous flow greater than 3l/h is 

detected for a certain period of time

The counter detects a flow continuous of 3 

l/h for X hours. (Default: 12)

Settable values (hours): 12/24/48/72

Check the absence of leaks in 

the water network / system

It automatically restores 

when the initial conditions are 

restored (flow <3 l/ h)

The payload contains the alarm status and 

the alarm activation date. After the reset, the 

status is updated

Removal alarm

Removal of the module from the 

counter is detected

A periodic check of the state of the plastic 

button is carried out

Check the correct mounting of 

the module on the meter

Reset the alarm via NFC

The payload contains the alarm status and 

the alarm activation date. After the reset, the 

status is updated

Magnetic fraud alarm

The presence of a magnetic field has 

been detected

The presence of a magnetic field is checked 

at regular intervals to prevent fraud

Check for the presence of a 

external magnetic field

Reset the alarm via NFC

The payload contains the alarm status and 

the alarm activation date. After the reset, the 

status is updated

7

Manuale utente v1.2

IWM-TX5

Summary of Contents for IWM-TX5

Page 1: ...IWM TX5 User manual EN...

Page 2: ...ed with particular attention to ease of use and reliability in the WM Bus system The device is delivered in sleep mode All functions radio transmission included are deactivated The module is activated...

Page 3: ...fety and the RED Directive 2014 53 EU The warranty and correct functioning are void if the identification plate and seals applied to the instrument are removed or damaged It is forbidden to transport...

Page 4: ...when cables are routed outside the building use increased protection against electrical interference The device may only be installed in frost free areas Problem Cause Solution It does not transmit v...

Page 5: ...ll the IWM TX5 module away from metal objects or any potential radio shielding in a place protected from tampering The device could be configured by using the BMetering NFC Config App The installer ha...

Page 6: ...n Preconfigured radio parameters Walk by mode Transmission frequency every 60 seconds Transmission interval 5 7 days no weekend every month Encryption disabled default 12 monthly historical data No se...

Page 7: ...te After the reset the status is updated Low battery alarm A battery voltage of less than 2 65V has been detected It is activated when the battery voltage drops below the 2 65V threshold Permanent err...

Page 8: ...onment which could cause an explosion or a leak of gases or flammable liquids Always dispose of batteries in compliance with current regulations Always use original spare parts authorized by the manuf...

Page 9: ...7 NFC fraud alert Protection class IP65 on request IP68 Certifications CE from 1 C to 55 C from 20 C to 70 C WM BUS 868 MHz T1 AES 128 Co processor cryptographic max 10 years Lithium 3 0V 1 8 Ah Indu...

Page 10: ...nual v1 2 Contact Info B METERS srl Via Friuli 3 33050 Gonars UD ITALY Tel 39 0432 931415 39 0432 1690412 Fax 39 0432 992661 E Mail vendite info info bmeters com E Mail assistenza ticket bmeters com W...