background image

IWM-TX5

6

User Manual v1.2

OPERATING MODES - RADIO ACTIVATION

Once the module is installed, the radio transmission is activated automatically, after that 5 liters of water have 

passed through the meter.

It is possible to force the activation and deactivation of radio transmission through the NFC app.

RADIO PARAMETERS

Wireless M-BUS compatible

As soon as the radio operating mode is activated, the device sends a radio telegram according to Wireless 

M-BUS, T1 mode (one-way transmission).

Preconfigured radio parameters

Walk-by mode:

•  Transmission frequency: every 60 seconds.

•  Transmission interval: 5/7 days (no weekend), every month

•  Encryption: disabled (default)

•  12 monthly historical data

•  No sending of internal date and time

AMR mode (Default):

•  Transmission frequency: every 200 seconds

•  Transmission interval: 7/7 days, every month

•  Encryption: disabled (default)

•  No historical data

•  No sending of internal date and time

The configuration and setting of further parameters / thresholds can be done via NFC and its app (BMetering 

NFC App). An ‘Active’  field is provided in the 

BMetering NFC Config App

 that allows you to ‘force’ the radio 

transmission by ignoring the  passage of the 5 liters.

Summary of Contents for IWM-TX5

Page 1: ...IWM TX5 User manual EN...

Page 2: ...ed with particular attention to ease of use and reliability in the WM Bus system The device is delivered in sleep mode All functions radio transmission included are deactivated The module is activated...

Page 3: ...fety and the RED Directive 2014 53 EU The warranty and correct functioning are void if the identification plate and seals applied to the instrument are removed or damaged It is forbidden to transport...

Page 4: ...when cables are routed outside the building use increased protection against electrical interference The device may only be installed in frost free areas Problem Cause Solution It does not transmit v...

Page 5: ...ll the IWM TX5 module away from metal objects or any potential radio shielding in a place protected from tampering The device could be configured by using the BMetering NFC Config App The installer ha...

Page 6: ...n Preconfigured radio parameters Walk by mode Transmission frequency every 60 seconds Transmission interval 5 7 days no weekend every month Encryption disabled default 12 monthly historical data No se...

Page 7: ...te After the reset the status is updated Low battery alarm A battery voltage of less than 2 65V has been detected It is activated when the battery voltage drops below the 2 65V threshold Permanent err...

Page 8: ...onment which could cause an explosion or a leak of gases or flammable liquids Always dispose of batteries in compliance with current regulations Always use original spare parts authorized by the manuf...

Page 9: ...7 NFC fraud alert Protection class IP65 on request IP68 Certifications CE from 1 C to 55 C from 20 C to 70 C WM BUS 868 MHz T1 AES 128 Co processor cryptographic max 10 years Lithium 3 0V 1 8 Ah Indu...

Page 10: ...nual v1 2 Contact Info B METERS srl Via Friuli 3 33050 Gonars UD ITALY Tel 39 0432 931415 39 0432 1690412 Fax 39 0432 992661 E Mail vendite info info bmeters com E Mail assistenza ticket bmeters com W...