8
User Manual v1.4.3
HYDRODIGIT
Preconfigured radio parameters:
• Transmission frequency: every 12 hours (current values).
• Transmission interval: 7/7d, 0/24h.
• Transmitted data: volume, reverse flow, diameter, medium, alarms
It is possible to change the configuration parameters into Walk-By mode with an USB to IR interface (B
METERS mod. UC-Cable) and the B Metering software:
• Transmission frequency: every 6 hours (current values)
• Temperature data sending
• Transmitted data: volume, reverse flow, diameter, medium, alarms, temperature (if enabled)
• ABP mode and relative keys
L Wireless MBUS OMS v4 (COMBO, output configuration L Wireless MBUS OMS v4)
As soon as radio operation mode is activated, the meter sends join requests to the Network Server where
it has been provisioned, according to LoRaWAN transmission standard. Moreover, it turns on the Wireless
M-BUS OMS v4 mode T1 (unidirectional transmission) interface.
During this process, the radio icon on the display will blink every second. If the procedure ends well, the icon
will remain on and stable, otherwise it will turn off.
Preconfigured radio parameters (
LoRaWAN
):
• Transmission frequency: every 12 hours (current values).
• Transmission interval: 7/7d, 0/24h.
• Transmitted data: volume, reverse flow, diameter, medium, alarms
Preconfigured radio parameters (
wM-Bus
):
• Transmission frequency: every 60 seconds.
• Transmission interval: from Monday to Friday, from 8 to 18 h.
• Encryption: disabled
• Historical data (12 months)
• Transmitted data volume, date time, reverse flow, alarms, leakage alarm, fraud alarm (Qmax overflow or
backward flow detection).
It is possible to change the configuration parameters into Walk-By mode with an USB to IR interface
(B METERS mod. UC-Cable) and the B Metering software:
LoRaWAN
:
• Transmission frequency: every 6 hours (current data)
• Temperature data sending
• Transmitted data: volume, backward flow, diameter, medium, alarms, temperature (if enabled)
• ABP mode and relative keys