4
HYDROCLIMA 2 - User Manual
Installation on radiator heaters
9. To ensure the heating cost calculation is correct, it is necessary to
install all allocators of a given radiators at the
same height
.
a. In the case of an even number of heating elements the allocator (heat sink) should be installed in the middle of the
width and at 75% of the height measured from the bottom of the radiator:
b. In the case of an even number of heating elements, when the radiator’s mounting pin is located in the middle, the
allocator (heat sink) can be moved one heating element toward the radiator’s supply. The installation height should
remain the same (75%):
10. When performing the installation or stocktaking of allocators, the rooms in which they are located should be
described in clockwise order. (See image below)
The allocator (heat sink) should be installed using a properly selected mounting bracket.
Please consult the following installation cases:
Summary of Contents for HYDROCLIMA 2
Page 1: ...v 1 0...