Pay attention to the angular or sharp protrusions in the threads, flanges and measuring tube.  
Therefore, it is recommended to wear protective gloves.

The device shall be used in such a way as to minimize the potential for human contact during 
normal operation. To avoid the possibility of exceeding radio frequency exposure limits, human 
proximity to receivers with integrated antenna should not be less than 20 cm (8 inches) during 
normal operation.

Do not expose the meter to the sun and heat sources. Do not attempt to burn the device.

In case of danger of frost, empty the system and, if necessary, remove the meter.

To clean the device externally use a soft cloth and moistened with water. Do not wash with 
high-pressure jets or soak the device in water. Avoid contact with oils and solvent. Do not use 
alcohol or detergents.

Do not damage the casing of the device. In the event of collisions of blunt objects on the front 
of the display, it can be irreparably damaged and lose the IP65 degree of protection. Install in 
areas protected against impacts. If the protective casing breaks, contact customer service.

The display turns off. To activate it, press the button on the device. The display remains active 
for 60 seconds.

The meter is not suitable for drinking water but is suitable for circulating water in central heating 
systems. The quality of the water has to be as specified by the CEN/TR 16911 regulation.

Do not twist, wrap, extend or shorten the cables of the temperature probes and the cable that 
connects the electronic unit to the part of the lower-case body.

The thermal energy meter can be installed only in areas protected from frost.

The thermal energy meter must be protected against pressure shocks in the pipeline.

Slowly fill the pipe with water at the end of the installation.

After installing the meter perform a leak test of the system.

Assemble or disassemble the meter only after depressurization of the system.

The meter does not have lightning protection.

Thermal energy meters do not require special protection against electrical interference; howe-
ver, electromagnetic interference must be avoided.

If transmission network interfaces are used, especially when cables are routed outside the 
building, use increased protection against electrical interference.

Summary of Contents for HYDROCAL-M4

Page 1: ...ons in this manual For further technical clarification please contact Customer Service Installation should be carried out exclusively by qualified personnel The reference standard for the instrument i...

Page 2: ...Remove the device from the package only at the time of installation to protect it from damage and dirt The air transport of active radio devices is prohibited Carefully observe the instructions in the...

Page 3: ...areas protected against impacts If the protective casing breaks contact customer service The display turns off To activate it press the button on the device The display remains active for 60 seconds T...

Page 4: ...elines and directives B METERS disclaim all liability for consequential damage resulting from the use of third party gaskets such as corrosion of sealing surfaces and threads Problem Cause Solution Di...

Page 5: ...the arrow in relief on the brass body and respecting the prescribed position To ensure proper measurement make sure that there is no air inside the pipe and that the flow is clean and free of debris p...

Page 6: ...ly probe must be installed in a ball valve or in a socket mounted on the flow pipe and complies with the requirements of the sensor itself Vice versa the version for installation on the inlet pipe the...

Page 7: ...3 Heating data index 4 Cooling data index 5 Circuit 1 2 pulse emitter external module 6 Return temperature index 7 Indicator of sub level presence 8 Supply temperature index 9 Battery level indicator...

Page 8: ...s T2 button 2 Units of measurement set Unit select through the left right button T1 T2 one of the following items 1 Joule 2 MJ 3 GJ 4 kWh 5 MWh Holding down the right button for 3 seconds can temporar...

Page 9: ...pressing the T1 button you can choose the desired level while pressing the T2 button you can view the sublevels of the preset level After 60 seconds without iteration the display turns off If no butt...

Page 10: ...IN 2 Type of pulse 4 02 MEMORY DAY 2 4 02 1 HEAT J MJ GJ kWh MWh 4 02 2 COOL J MJ GJ kWh MWh 4 02 3 IN 1 Type of pulse 4 02 4 IN 2 Type of pulse 6 INDEX INF UM 6 xx MONTLY MEMORY 1 6 xx 1 HEAT J MJ GJ...

Page 11: ...rrors and faults When one or more anomalies occur the thermal energy meter will report the recorded error and show the following icon on the display If the NFC or IR interface is used the icon will bl...

Page 12: ...n be activated and further details on the thermal energy meter refer to the complete User manual available at www bmeters com 10 Battery and replacement procedures The thermal energy meter constantly...

Page 13: ...asuring temperature range cooling 0 2 C 90 C Temperature range difference cooling 0 2 K 90K Counting operating conditions start Heating 1K counting enabling conditions Cooling 0 2K Max measurable powe...

Page 14: ...angerous to human health and the environment but if abandoned in the environment it negatively impacts the ecosystem The symbol of the crossed out bin present on the label placed on the appliance indi...

Reviews: