10"
(254mm)
"A/D" CAP
3" Dia.
(76mm)
2 11/16"
(68mm)
"B"/"E" CAP
(203mm)
8"
(76mm)
3" Dia.
2 11/16"
(68mm)
"C" CAP
(178mm)
7"
(76mm)
3" Dia.
Patented 360HD™
Mounting System
"B"/"E" CAP
3"
(76mm)
1"
(25mm)
"A"/"D" CAP
3"
(76mm)
5"
(127mm)
"C" CAP
2"
(51mm)
2 11/16"
(68mm)
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
RELEASED DATE
04/21/2021
REFERENCE NUMBER
INS-2845-00
6. Loosen, then remove two (2) #4-40 screws
from LED module using a .050” allen wrench.
7. Carefully remove LED module from heatsink.
Do not pull on connector or wiring. Handle
with care.
5. Loosen four (4) #6-32 screws on wall wash
optic holder using a 7/64” allen wrench, then
gently pull away to remove from heatsink.
4. Detach heatsink from fixture body via quick
disconnect.
Do not pull on connector or wiring. Handle
with care.
Fragile! Do not pull on connector or wiring.
Handle with care.
8. Use small pick tool to push connector off
LED board through two small slots behind
connector. Once loose, lift connector upwards
and off board.
9. Spread thin, even layer of thermal paste on
back of new LED module. Place new LED
module onto heatsink, lining up module
with holes for screws. Tighten two (2) #4-40
screws using .050” Allen wrench to secure
LED module to heatsink.
YOSEMITE SERIES
Integral -LED
Standard Installation
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION
INSTRUCTIONS
11. Place wall wash optic over LED module, lining
up screw locations with holes in heatsink.
Secure wall wash optic to heatsink with four
(4) #6-32 screws using a 7/64” allen wrench.
12. Attach heatsink to fixture via quick disconnect.
10. Press connector straight downwards into slot
on module to snap into place.
Connector will only fit in one direction.