Remote Transformer
5. Make watertight connections from remote
transformer to fixture source leads using
waterproof wire connectors (By Others).
See
wiring diagram.
4. Pull low voltage wire or pull branch circuit
wires necessary for installation (By Others)
through anchor base.
Anchor base can accommodate up to two (2)
1/2” conduits.
7. Place fixture on anchor base and tighten four
(4) #10-32 stainless steel button head cap
screws using a 1/8” Allen wrench.
120V
12V
Fixture
COM
Remote
Transformer
COM
120V
12V
Fixture
COM
GROUND
Integral
Transformer
COM
GROUND
Integral Transformer
6.
Use waterproof wire connectors
(By Others) to make watertight connections
from transformer primary leads to branch circuit
wires. Connect incoming ground to ground wire
provided in fixture body.
See wiring diagram.
WIRING DIAGRAM
3.
50
1.
50
1. Determine suitable anchors (By Others) to
attach anchor base to architectural surface.
2. Place provided template in final mounting
position according to designed lighting plan.
3. Drill holes into surface for maximum 7/16”
fasteners (By Others) on locations illustrated
on template. Base mounting hole locations is
1-1/2” on center by 3-1/2” on center apart.
PROJECT:
TYPE:
(33mm)
1 5/16"
(76mm)
3"
Specify
Length
BS-LED
S000891
1 3/8"
(35mm)
(4) 3/8" Dia. (10mm)
Bolt Holes
Slip Anchor
(38mm)
2" Dia. (51mm)
O.C.
Slip Conduit Hole
1 1/2"
3 1/2" O.C.
(89mm)
68° Angle = A
90° Angle = B
5"
(127mm)
PS™ / BS™/ PSL™ / BSL™
Installation Instructions
REFERENCE
NUMBER
INS000733
TECHNOLOGY
with
TECHNOLOGY
Anchor Base Installation
TRANSFORMER HOUSING MUST BE INSTALLED ABOVE GRADE.
TRANSFORMER HOUSING INSTALLED BELOW GRADE WILL VOID WARRANTY
& Low Voltage
120V
12V
Fixture
COM
Remote
Transformer
COM
120V
12V
Fixture
COM
GROUND
Integral
Transformer
COM
GROUND
WIRING DIAGRAM
8. Use 1/8” Allen wrench to loosen #10-24 stainless
faceplate screws to remove faceplate. for access
to source.