1 3/8"
35mm
68° Angle = A
S000733
PS-LED
1 3/8"
(35mm)
3/8" Dia. (10mm)
Bolt Holes
(38mm)
Slip Anchor
2" Dia. (51mm)
Slip Conduit Hole
1 1/2" O.C.
3 1/2"O.C.
(89mm)
Optional
Stability
Flange
5 7/8" Dia.
(149mm)
8"
(203mm)
3"
76mm
90° Angle = B
5"
(127mm)
Standard
Base Pipe
Stake
PS™ / PSL™
Installation Instructions
REFERENCE
NUMBER
INS000733.1
Finished grade
Concrete
Finished grade
Finished grade
Optional
Stability Flange
Pea gravel
or sand
Finished grade
Pea gravel
or sand
Pea gravel
or sand
Above Ground
Finished grade
Pea gravel
or sand
Pea gravel
or sand
Above Ground
Finished grade
Concrete
Below Ground
Finished grade
Pea gravel
or sand
3. Pull branch circuit wiring necessary for
installation (By Others) to Power Pipe™. Place
Power Pipe™ in hole.
Allow for additional cable to make connections
to fixture leads and future service. Do not cut
PVC.
Finished grade
Concrete
Finished grade
Finished grade
Optional
Stability Flange
Pea gravel
or sand
Finished grade
Pea gravel
or sand
Pea gravel
or sand
Above Ground
Finished grade
Pea gravel
or sand
Pea gravel
or sand
Above Ground
Finished grade
Concrete
Below Ground
Finished grade
Pea gravel
or sand
2. Slide optional Stability Flange onto Power
Pipe™. Use optional Stability Flange to aid in
installation of Power Pipe™.
1. Excavate trench according to designed lighting
plan. Dig hole a minimum of 18” deep and 10”
wide to accommodate Power Pipe™ at desired
fixture locations.
Power Pipe with Anchor Base Mounting Option
Finished grade
Concrete
Finished grade
Finished grade
Optional
Stability Flange
Pea gravel
or sand
Finished grade
Pea gravel
or sand
Pea gravel
or sand
Above Ground
Finished grade
Pea gravel
or sand
Pea gravel
or sand
Above Ground
Finished grade
Concrete
Below Ground
Finished grade
Pea gravel
or sand
4. Back fill with pea gravel or sand prior to pour.
Finished grade
Concrete
Finished grade
Finished grade
Optional
Stability Flange
Pea gravel
or sand
Finished grade
Pea gravel
or sand
Pea gravel
or sand
Above Ground
Finished grade
Pea gravel
or sand
Pea gravel
or sand
Above Ground
Finished grade
Concrete
Below Ground
Finished grade
Pea gravel
or sand
5. Pour concrete (By Others).
Label on Power Pipe™ indicates installation
depth with finished grade.
Remote
Transformer
Remote Transformer
6. Make watertight connections from remote 12V
transformer to LED source leads (18 gauge wire)
using waterproof wire connectors (By Others).
See wiring diagram.
TECHNOLOGY
with
TECHNOLOGY
TRANSFORMER HOUSING MUST BE INSTALLED ABOVE GRADE. POWER PIPE™ IS LABELED AT GRADE LEVEL.
TRANSFORMER HOUSING INSTALLED BELOW GRADE WILL VOID WARRANTY
& Low Voltage
Soil Prep
Conduit
trench
B. Dig hole 10” wide and 24” deep.
Conduit
Trench
Excavated
for Housing
C. Prep soil according to DIG-IT Guide.
A. Determine Soil Type by referencing DIG-IT Guide.
Prep soil according to DIG-IT Guide.