background image

RELEASE DATE

7-13-16

REFERENCE

 

NUMBER

INS-1341-00

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY 

DESCRIBE.  REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.

1/8” Allen Wrench
Wire Connectors
Level
Phillips Screwdriver

Warning

Low Voltage

Hot Surface

NEEDED

FOR 

INSTALLATION:

By Others

Silicone Filled

Wire Nuts

O-Ring

HP2 Shallow

Housing

Concrete Pour 

Collar (CPC)

Faceplate

Proper soil preparation is recommended before installation. See the DIG-IT guide at www.bklighting.com/dig-it for more information.

HP

2

 SERIES™

Shallow Housing - Halogen (MR16)

Remote Transformer Installation Instructions

Soil Prep

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS

Conduit
trench

A.  Determine Soil Type by referencing 

DIG-IT Guide. 

B.  Dig hole 24” wide and 8” deep.

Conduit
Trench

Excavated 
for Housing

C.  Prep soil according to DIG-IT Guide.

• 

Product must be installed by a qualified person in a manner 

consistent with its intended use and in compliance with the 

National Electrical Code, Canadian Electrical Code, and all Local 

and Provincial Codes. 

• 

Follow product label information and instructions.

• 

Qualified Personnel must perform all servicing or relamping of 

this product.

• 

Before wiring to power supply and during servicing or relamping, 

turn off power at fuse or circuit breaker before service.

• 

The use of accessory equipment not recommended by the 

manufacturer or installed contrary to instructions may cause an 

unsafe condition. The use of damaged components may cause 

an unsafe condition and void product warranty.

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY 

AND INSTALLATION INSTRUCTIONS

• 

Do not block light emanating from product in whole or part, 

as this may cause an unsafe condition.

• 

Never operate the fixture with missing or damaged lens.  

Lens must be cleaned on regular basis.

• 

Entire fixture may become extremely hot. Do not touch hot 

lens or fixture body. Do not touch the lamp at any time. Use 

a clean, dry, soft cloth to handle the lamp. Oil from skin may 

damage the lamp and cause it to rupture.

• 

Replace lamp only with correct wattage and type of lamp 

marked on fixture label.

• 

All gaskets, o-rings and sealing surfaces must be kept clean 

during installation and service; failure to do this may cause an 

unsafe condition and void product warranty. 

INSTRUCTIONS PERTAINING TO 

A RISK OF FIRE, OR INJURY TO 

PERSONS IMPORTANT SAFETY 

INSTRUCTIONS

Lighted lamp is HOT!

WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:  

Turn off/unplug and allow to cool before replacing lamp.  

Lamp gets HOT quickly! Contact only switch/plug when 

turning on.  

Do not touch hot lens, guard, or enclosure (see diagram/

picture).  

Keep lamp away from materials that may burn.  

Do no touch the lamp at any time. Use a soft cloth. Oil 

from skin may damage lamp.  

Do not operate the luminaire fitting with a missing or 

damaged shield.  

 

SAVE THESE INSTRUCTIONS

 

·  Suitable for wet locations ·  Suitable for recessed in ground locations

IMPORTANT LISTINGS AND CERTIFICATIONS

Opti

Lock® 

Assembly

Thumbscrew

Optional 

Accessory 

Holder

Retaining

Clip

Summary of Contents for Precision2 HP2 Series

Page 1: ...relamping turn off power at fuse or circuit breaker before service The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe conditio...

Page 2: ...pavers etc to be level with the top of the temporary cover Soil installation is not drive over rated 7 For concrete installation Fill the hole around the fixture housing to 12 below the finished grad...

Page 3: ...tallation Instructions 3 Place OptiLock in HP2 housing and align keyhole notch under one of 3 8 screw heads Rotate horizontally to desired aiming position then tighten 2 8 Phillips screws using Philli...

Page 4: ...8 3 5P SFEVDF UIF SJTL PG 3 03 63 50 1 340 4 5VSO PGG VOQMVH BOE BMMPX UP DPPM CFGPSF SFQMBDJOH MBNQ BNQ HFUT 05 RVJDLMZ POUBDU POMZ TXJUDI QMVH XIFO UVSOJOH PO P OPU UPVDI IPU MFOT HVBSE PS FODMPTVSF...

Page 5: ...FS DMJQ OTFSU VQ UP BDDFTTPSJFT Insert any accessory lens with the smooth side towards the lamp If using a honeycomb baffle position it farthest from the lamp 1JODI SFUBJOFS DMJQ UBCT BOE MJOF VQ OPUD...

Page 6: ...UJPO BOE WPJE QSPEVDU XBSSBOUZ IMPORTANT SAFETY INFORMATION READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS t P OPU CMPDL MJHIU FNBOBUJOH GSPN QSPEVDU JO XIPMF PS QBSU BT UIJT NBZ DBVTF...

Page 7: ...BUF UP BMMPX BDDFTTPSZ UP SPUBUF GSFFMZ DDFTTPSZ DBO SPUBUF JOEFQFOEFOUMZ PG GBDFQMBUF 8IFO TFU JO GJOBM QPTJUJPO UJHIUFO TFU TDSFXT VTJOH w MMFO XSFODI OTUBMM GBDFQMBUF VTJOH w MMFO XSFODI BOE IBOE U...

Page 8: ...ply and during servicing or relamping turn off power at fuse or circuit breaker before service The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions...

Page 9: ...s etc to be level with the top of the temporary cover Soil installation is not drive over rated 7 For concrete installation Fill the hole around the fixture housing to 12 below the finished grade with...

Page 10: ...nsformer Installation Instructions 3 Place OptiLock in HP2 housing and align keyhole notch under one of 3 8 screw heads Rotate horizontally to desired aiming position then tighten 2 8 Phillips screws...